跳转至内容
Merck
CN

49540

Supelco

七氟丁酸 溶液

0.5 M in H2O, LiChropur, suitable for ion pair chromatography

登录查看公司和协议定价

别名:
HFBA 溶液, 全氟丁酸 溶液
经验公式(希尔记法):
C4HF7O2
CAS号:
分子量:
214.04
MDL编号:
UNSPSC代码:
12000000
PubChem化学物质编号:
NACRES:
NB.21

描述

concentrate

质量水平

形式

liquid

质量

LiChropur

浓度

0.5 M in H2O

技术

ion pair chromatography: suitable

SMILES字符串

OC(=O)C(F)(F)C(F)(F)C(F)(F)F

InChI

1S/C4HF7O2/c5-2(6,1(12)13)3(7,8)4(9,10)11/h(H,12,13)

InChI key

YPJUNDFVDDCYIH-UHFFFAOYSA-N

应用

LC/MS的离子对试剂

法律信息

LiChropur is a trademark of Merck KGaA, Darmstadt, Germany

象形图

Corrosion

警示用语:

Danger

危险声明

危险分类

Skin Corr. 1A

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Ulrika Eriksson et al.
Environmental science and pollution research international, 20(11), 7940-7948 (2013-04-17)
Diet and drinking water are suggested to be major exposure pathways for perfluoroalkyl substances (PFASs). In this study, food items and water from Faroe Islands sampled in 2011/2012 were analyzed for 11 perfluoroalkyl carboxylic acids (PFCAs) and 4 perfluoroalkane sulfonic
V Gellrich et al.
Chemosphere, 87(9), 1052-1056 (2012-03-07)
Perfluorinated compounds (PFCs) can be detected worldwide in both, soil and water. In order to study the leaching behavior of this heterogeneous group of compounds in soil, flow-through column experiments have been conducted. Ten perfluoro carboxylates and four perfluoro sulfonates
Kaberi P Das et al.
Toxicological sciences : an official journal of the Society of Toxicology, 105(1), 173-181 (2008-05-31)
Perfluorobutyrate (PFBA) is a perfluoroalkyl acid (PFAA) found in the environment. Previous studies have indicated developmental toxicity of PFAAs (perfluorooctane sulfonate [PFOS] and perfluorooctanoate [PFOA]); the current study examines that of PFBA. PFBA/NH4(+) was given to timed-pregnant CD-1 mice by
Merja R Häkkinen et al.
Journal of pharmaceutical and biomedical analysis, 45(4), 625-634 (2007-10-20)
A reversed phase liquid chromatography-electrospray ionization-tandem mass spectrometric method (RP-LC-ESI-MS/MS) was developed to separate and detect polyamines with minimal sample pre-treatment and without any derivatization. Prior to MS/MS analysis, a complete chromatographic separation of polyamines was achieved by a linear
Yuko Murakami et al.
Organic & biomolecular chemistry, 12(48), 9887-9894 (2014-10-31)
Desmosine-CH2, an analog of the elastic tissue degradation biomarker desmosine, can be regarded as a potential internal standard for precise quantification of desmosines by LC-MS/MS. In this study, the chemical synthesis of desmosine-CH2 was completed in 22% overall yield in

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门