登录 查看组织和合同定价。
选择尺寸
关于此项目
线性分子式:
(CH3)2CHCH2C(CH3)3
化学文摘社编号:
分子量:
114.23
UNSPSC Code:
41116107
NACRES:
NA.24
PubChem Substance ID:
EC Number:
208-759-1
Beilstein/REAXYS Number:
1696876
MDL number:
InChI key
NHTMVDHEPJAVLT-UHFFFAOYSA-N
InChI
1S/C8H18/c1-7(2)6-8(3,4)5/h7H,6H2,1-5H3
SMILES string
CC(C)CC(C)(C)C
grade
analytical standard
vapor density
3.9 (vs air)
vapor pressure
41 mmHg ( 21 °C)
autoignition temp.
745 °F
shelf life
limited shelf life, expiry date on the label
expl. lim.
6 %
manufacturer/tradename
H&D Fitzgerald Ltd.
mp
−107 °C (lit.)
density
0.692 g/mL at 25 °C (lit.)
application(s)
cleaning products
cosmetics
environmental
flavors and fragrances
food and beverages
industrial qc
personal care
petroleum
pharmaceutical (small molecule)
format
mixture
Application
This density CRM is used for the calibration of all types of laboratory density meters in the test temperature range of 10 to 25 °C.
Features and Benefits
- Manufactured and verified in anISO 17025 accredited laboratory, as per UKAS
- Carries an associated uncertaintyof +/- 0.010 Kg/m3
- Provided in a sealed glassampoule of 10 mL to assure safe delivery
- Accompanied with a certificate of analysis (CoA)having information on the expiry date for an effective audit
signalword
Danger
hcodes
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Central nervous system
存储类别
3 - Flammable liquids
wgk
WGK 2
flash_point_f
10.4 °F - closed cup
flash_point_c
-12 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
危险化学品
此项目有
M Dolors Benaiges et al.
Biotechnology progress, 26(5), 1252-1258 (2010-10-15)
The characterization of the recombinant Candida rugosa Lip2 (r-Lip2) isoenzyme obtained from fed-batch cultures of Pichia pastoris under PAOX promoter was carried out, determining the optimal pH and temperature as well as their catalytic performance in both hydrolysis and synthesis
Choline acetate enhanced the catalytic performance of Candida rogusa lipase in AOT reverse micelles.
Luyan Xue et al.
Colloids and surfaces. B, Biointerfaces, 105, 81-86 (2013-01-29)
Choline acetate is an ionic liquid composed of a kosmotropic anion and a chaotropic cation. According to Hofmeister series, a kosmotropic anion and/or a chaotropic cation could stabilize an enzyme, thereby facilitating the retention of the catalytic activity of the
Jonas Andersson et al.
Physics in medicine and biology, 56(2), 299-314 (2010-12-17)
A method to correct for the general recombination losses for liquid ionization chambers in continuous beams has been developed. The proposed method has been derived from Greening's theory for continuous beams and is based on measuring the signal from a
Yufeng Zhang et al.
Journal of chromatography. A, 1252, 67-73 (2012-07-10)
In this study, a polyethylene Pasteur pipette-based ultrasound-assisted emulsification microextraction (USAEME) applying low-density organic solvent was successfully developed for the extraction of trace levels of organochlorine pesticides (OCPs) in water samples and followed by gas chromatography-mass spectrometry (GC-MS) analysis. In
Luciane Batistella et al.
Bioprocess and biosystems engineering, 35(3), 351-358 (2011-07-23)
Both stability and catalytic activity of two commercial immobilized lipases were investigated in the presence of different organic solvents in ultrasound-assisted system. In a general way, for Novozym 435, the use of ethanol as solvent led to a loss of
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持


