跳转至内容
Merck
CN

394904

Supelco

五氟丙酸酐

for GC derivatization, LiChropur, 99%

别名:

PFPA, 全氟丙酸酐

登录查看公司和协议定价


About This Item

线性分子式:
(CF3CF2CO)2O
CAS号:
分子量:
310.05
Beilstein:
1806446
EC 号:
MDL编号:
UNSPSC代码:
12000000
PubChem化学物质编号:
NACRES:
NA.22

等级

for GC derivatization

质量水平

方案

99%

表单

liquid

质量

LiChropur

反应适用性

reagent type: derivatization reagent
reaction type: Acylations

技术

gas chromatography (GC): suitable

沸点

69-70 °C/735 mmHg (lit.)

密度

1.571 g/mL at 25 °C (lit.)

SMILES字符串

FC(F)(F)C(F)(F)C(=O)OC(=O)C(F)(F)C(F)(F)F

InChI

1S/C6F10O3/c7-3(8,5(11,12)13)1(17)19-2(18)4(9,10)6(14,15)16

InChI key

XETRHNFRKCNWAJ-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

应用

Learn more in the Product Information
Derivatization reagent used in a GC-MS analysis of stereoisomer content of synthetic peptides. Also used in a GC-MS detection method for synephrine in dietary supplements.
For the preparation of volatile pentafluoropropionyl derivatives of a wide range of compounds, for example, amines and alcohols, for EC/GC.
Pentafluoropropionic anhydride (PFPA) was used as derivatization reagent for urine samples to determine the presence of codeine, morphine, 6-monoacetylmorphine, ethylmorphine, and dihydrocodeine using GC-MS in selected ion monitoring (SIM) mode. It was also used to derivatize the dry pericardial fluid sample extracts for quantification of cocaine, benzoylecgonine, and cocaethylene in pericardial fluid using GC-MS.

包装

Clear borosilicate glass, high hydrolytic resistance (Type I)

法律信息

LiChropur is a trademark of Merck KGaA, Darmstadt, Germany

象形图

Corrosion

警示用语:

Danger

危险声明

危险分类

Skin Corr. 1B

补充剂危害

储存分类代码

8A - Combustible corrosive hazardous materials

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Emilia Marchei et al.
Journal of pharmaceutical and biomedical analysis, 41(4), 1468-1472 (2006-05-16)
A simple and rapid procedure based on gas chromatography-mass spectrometry (GC-MS) is described for determination of synephrine, active principle of Citrus aurantium plant, in solid and liquid dietary supplements. After the addition of 3,4-methylenedioxypropylamphetamine as internal standard (I.S.), a liquid-liquid
Ralf Pätzold et al.
Chirality, 18(7), 551-557 (2006-05-10)
Synthetic dipeptides comprising mixtures of enantiomers, diastereomers, or sequential isomers were converted into their N-perfluoroacetyl dipeptide esters (perfluoroacetyl: trifluoroacetyl, pentafluoroacetyl, heptafluorobutyryl; ester: methyl, 1-propyl, 2-propyl, 2,2,2-trifluoroethyl) and analyzed by GC-MS on the chiral stationary phases Chirasil-L-Val and Lipodex-E using helium
Comparison of RapiTest? with Emit? d, au? and GC-MS for the Analysis of Drugs in Urine.
Korte, T., et al.
Journal of Analytical Toxicology, 21, 49-53 (1997)
María Teresa Contreras et al.
Journal of analytical toxicology, 31(2), 75-80 (2007-06-01)
A method is described for the simultaneous quantification of cocaine, benzoylecgonine, and cocaethylene in pericardial fluid. Pericardial fluid samples from autopsy casework involving cocaine-related deaths and deaths unrelated to drug abuse were collected. The extraction of cocaine and its metabolites
F F Hsu et al.
Analytical biochemistry, 216(2), 401-405 (1994-02-01)
We report an isotope dilution mass spectrometry method using capillary gas chromatography negative ion chemical ionization for the determination of cortisol in human plasma. Cortisol was derivatized with pentafluoropropionic anhydride at room temperature and measured by selected ion monitoring of

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.