推荐产品
等级
analytical standard
质量水平
保质期
limited shelf life, expiry date on the label
浓度
~100 μg/mL in acetonitrile
技术
HPLC: suitable
gas chromatography (GC): suitable
应用
cleaning products
cosmetics
food and beverages
personal care
包装形式
single component solution
储存温度
−20°C
SMILES字符串
CC(=O)OC[C@]12CCC(C)=C[C@H]1O[C@@H]3[C@H](O)[C@@H](OC(C)=O)[C@@]2(C)[C@]34CO4
InChI
1S/C19H26O7/c1-10-5-6-18(8-23-11(2)20)13(7-10)26-16-14(22)15(25-12(3)21)17(18,4)19(16)9-24-19/h7,13-16,22H,5-6,8-9H2,1-4H3/t13-,14-,15-,16-,17-,18-,19-/m1/s1
InChI key
AUGQEEXBDZWUJY-ZLJUKNTDSA-N
一般描述
Certan Vial
应用
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
分析说明
purity : ≥95.5% (HPLC)
警示用语:
Danger
危险分类
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
储存分类代码
3 - Flammable liquids
WGK
WGK 2
闪点(°F)
35.6 °F
闪点(°C)
2 °C
个人防护装备
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
危险化学品
高风险级别生物产品--毒素类产品
The Cochrane database of systematic reviews, 5, CD006278-CD006278 (2018-05-31)
Childhood apraxia of speech (CAS) affects a child's ability to produce sounds and syllables precisely and consistently, and to produce words and sentences with accuracy and correct speech rhythm. It is a rare condition, affecting only 0.1% of the general
IEEE transactions on medical imaging, 38(12), 2926-2936 (2019-05-29)
Recently, many reconstruction methods have been developed to improve the lateral resolution of acoustic-resolution photoacoustic microscopy (ARPAM) in out-of-focus regions. Though these methods enhance image resolution to some extent, they require advanced computational hardware and large computational time, especially for
Food chemistry, 267, 140-148 (2018-06-24)
In this report, a UPLC-ESI-MS/MS method for the simultaneous determination of aflatoxins, ochratoxin A, zearalenone, deoxynivalenol, fumonisins, T-2 and HT-2 toxins, fusarenone X, diacetoxyscirpenol, and 3- and 15-acetyldeoxynivalenol in feedstuffs was developed. A quadrupole-time-of-flight mass spectrometer detector (QTOF-MS) operating in
Computer methods and programs in biomedicine, 138, 13-22 (2016-11-26)
Eyes-closed-awake electroencephalogram (EEG) is a useful tool in the diagnosis of Alzheimer's. However, there is eyes-closed-awake EEG with dominant or rare alpha rhythm. In this paper, we show that random selection of EEG epochs disregarding the alpha rhythm will lead
The American journal of geriatric psychiatry : official journal of the American Association for Geriatric Psychiatry, 25(10), 1160-1170 (2017-06-10)
Early and preferential targeting of limbic structures by Alzheimer disease (AD)-related pathology suggests emotion dysregulation may serve as a marker of AD risk. We studied emotional verbal memory in two groups at risk for AD, amnestic mild cognitive impairment (aMCI)
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门