推荐产品
等级
analytical standard
保质期
limited shelf life, expiry date on the label
浓度
50 μg/mL in isooctane
技术
HPLC: suitable
gas chromatography (GC): suitable
应用
environmental
包装形式
single component solution
储存温度
2-8°C
SMILES字符串
Brc1ccc(Oc2cc(Br)c(Br)cc2Br)c(Br)c1Br
InChI
1S/C12H4Br6O/c13-5-1-2-9(12(18)11(5)17)19-10-4-7(15)6(14)3-8(10)16/h1-4H
InChI key
IZFQCEZFGCMHOM-UHFFFAOYSA-N
一般描述
BDE No 138 is an ubiquitous environmental contaminant with low acute toxicity, belonging to the class of polybrominated diphenyl ethers. It can find wide applications as additive flame-retardants in consumer products ranging from textiles to polymers.
应用
BDE No 138 may be used as an analytical reference standard for the quantification of the analyte in environmental samples using gas chromatography coupled to mass spectrometry (GC-MS) and selective pressurized liquid extraction followed by gas chromatography coupled to negative ion chemical ionization-mass spectrometry (GC-NCI-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
其他说明
The customer needs to make sure that the standard is homogeneous, this can be achieved by shaking, vortexing , or sonicating the ampoule before opening the ampoule. Care should be taken when opening the ampoule to avoid any injuries from the broken glass.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.
警示用语:
Danger
危险分类
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
靶器官
Central nervous system
储存分类代码
3 - Flammable liquids
WGK
WGK 2
闪点(°F)
10.4 °F - closed cup
闪点(°C)
-12 °C - closed cup
个人防护装备
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
危险化学品
Determination of potential sources of PCBs and PBDEs in sediments of the Niagara River.
Environmental Pollution (Barking, Essex : 1987), 139(2), 489-497 (2006)
Determination of decabromodiphenyl ether in sediments using selective pressurized liquid extraction followed by GC-NCI-MS.
Analytical and Bioanalytical Chemistry, 378(3), 610-614 (2004)
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门