推荐产品
等级
for chromatography
质量水平
表单
liquid
反应适用性
reagent type: oxidant
应用
diagnostic assay manufacturing
hematology
histology
储存温度
room temp
SMILES字符串
O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.OP(O)(O)=O
InChI
1S/12Mo.H3O4P.36O/c;;;;;;;;;;;;1-5(2,3)4;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;/h;;;;;;;;;;;;(H3,1,2,3,4);;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
InChI key
DHRLEVQXOMLTIM-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
磷钼酸溶液(PMA)作为一种现成的喷雾,它是Masson′三色染色液的成分。 它起到媒染剂的功能,在底物和初染剂之间形成桥梁。
应用
磷钼酸溶液是一种即用型的喷雾可用于类固醇、生物碱、抗氧化剂和萜类化合物的薄层色谱(TLC)和高效薄层色谱(HPTLC)分析的显色。
警示用语:
Danger
危险分类
Eye Dam. 1 - Flam. Liq. 2 - Ox. Liq. 3 - Skin Corr. 1B - STOT SE 3
靶器官
Central nervous system
储存分类代码
5.1B - Oxidizing hazardous materials
WGK
WGK 3
闪点(°F)
53.6 °F - closed cup
闪点(°C)
12.0 °C - closed cup
个人防护装备
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
法规信息
危险化学品
Talanta, 78(3), 1185-1189 (2009-03-10)
Interaction of luminol with phosphomolybdic, phosphovanadomolybdic and silicomolybdic acids was studied by examination of chemiluminescence spectra, measurement of ESR spectra, investigation of reaction order, and elucidation of inhibition effects. A scheme of the reaction mechanism is proposed.
Journal of chromatography. A, 903(1-2), 219-225 (2001-01-12)
A high-performance thin-layer chromatographic (HPTLC) method for the determination of the two main potato glycoalkaloids, alpha-chaconine and alpha-solanine, in different parts of the potato plant, is described. Samples were extracted with diluted aqueous acetic acid containing the ion-pairing reagent 1-pentanesulfonic
Analytica chimica acta, 688(2), 168-174 (2011-02-22)
The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids
Analytical biochemistry, 409(1), 144-149 (2010-10-26)
The classical malachite green (MLG) assay of phosphate, which added MLG after molybdate to the acidified reaction solutions of phosphate, tolerated interference from papaverine, sildenafil, and some similar hydrophobic amines. Resonance Rayleigh scattering signals, the alleviation of interference by poly(vinyl
Journal of chromatography. A, 1220, 82-91 (2011-12-27)
Barium-137m availed from a (137)Cs/(137m)Ba generator is an attractive industrial radiotracer for liquid flow rate measurement owing to its short half-life (T(1/2)=2.5 min) and emission of highly energetic gamma radiation (E(γ)=661.7 keV). Ammonium molybdophosphate (AMP) impregnated alumina microspheres (AMP-Al(2)O(3)), an
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门