推荐产品
蒸汽密度
2.7 (vs air)
质量水平
蒸汽压
11.69 psi ( 20 °C)
32.33 psi ( 55 °C)
等级
puriss. p.a.
检测方案
≥99.0% (T)
形式
liquid
自燃温度
1353 °F
expl. lim.
19 %
折射率
n20/D 1.389 (lit.)
n20/D 1.389
bp
52 °C (lit.)
mp
−112 °C (lit.)
密度
1.104 g/mL at 25 °C (lit.)
痕量阳离子
Al: ≤0.5 mg/kg
Ba: ≤0.1 mg/kg
Bi: ≤0.1 mg/kg
Ca: ≤0.5 mg/kg
Cd: ≤0.05 mg/kg
Co: ≤0.02 mg/kg
Cr: ≤0.1 mg/kg
Cu: ≤0.02 mg/kg
Fe: ≤0.5 mg/kg
K: ≤0.5 mg/kg
Li: ≤0.1 mg/kg
Mg: ≤0.1 mg/kg
Mn: ≤0.02 mg/kg
Mo: ≤0.1 mg/kg
Na: ≤0.5 mg/kg
Ni: ≤0.02 mg/kg
Pb: ≤0.1 mg/kg
Sr: ≤0.1 mg/kg
Zn: ≤0.1 mg/kg
SMILES字符串
CC(Cl)=O
InChI
1S/C2H3ClO/c1-2(3)4/h1H3
InChI key
WETWJCDKMRHUPV-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
乙酰氯(酰氯)是用于酯化和Friedel-Crafts酰化反应的乙酰化试剂。
应用
乙酰氯可以用作:
- 色谱-质谱联用(MS)降解聚氧乙二醇单烷基醚,测定乙氧基化程度的降解剂。
- 用于羧酸酯化、N-boc脱保护和磷酰胺溶剂分解反应的含醇试剂。
警示用语:
Danger
危险声明
危险分类
Eye Dam. 1 - Flam. Liq. 2 - Skin Corr. 1B
补充剂危害
WGK
WGK 1
闪点(°F)
closed cup
闪点(°C)
closed cup
个人防护装备
Faceshields, Gloves, Goggles
法规信息
危险化学品
Comparisons of O-acylation and Friedel-Crafts acylation of phenols and acyl chlorides and Fries rearrangement of phenyl esters in trifluoromethanesulfonic acid: Effective synthesis of optically active homotyrosines
Tetrahedron, 67(3), 641-649 (2011)
A rapid and simple method for the esterification of fatty acids and steroid carboxylic acids prior to gas-liquid chromatography
Clinica Chimica Acta; International Journal of Clinical Chemistry, 111(1), 91-98 (1981)
Metabolomics : Official journal of the Metabolomic Society, 12(12), 182-182 (2016-11-15)
Sensitive and specific assessment of the hepatic graft metabolism after liver transplantation (LTX) is essential for early detection of postoperative dysfunction implying the need for consecutive therapeutic interventions. Here, we assessed circulating liver metabolites of the cholesterol pathway, amino acids
The journal of physical chemistry. A, 114(27), 7275-7283 (2010-06-24)
In one-photon dissociation of gaseous acetyl chloride at 248 nm, time-resolved Fourier-transform infrared emission spectroscopy is used to detect the fragments of HCl, CO, and CH(2) in the presence of Ar or O(2). The high-resolution spectra of HCl and CO
Analytical chemistry, 79(11), 3989-3995 (2007-05-05)
The wide range of protein concentrations found in biological matrixes presents a formidable analytical challenge in proteomics experiments. It is predicted that low-abundance proteins are the likely clinically relevant targets in disease-based proteomics analyses. To effectively analyze low-abundance proteins by
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门