MPGPG02A1

Milli-Q

Millipak® Gold过滤器

For particulates- and bacteria-free water at the point of dispense of the Milli-Q® 7 series water purification systems.

别名:

Millipak® Gold 0.22 μm无菌过滤器

登录查看公司和协议定价


About This Item

UNSPSC代码:
41104212
eCl@ss:
33050190
NACRES:
NB.24

物料

polyethersulfone filter

质量水平

无菌性

sterile

特点

hydrophilic

包装

pkg of 1 unit

制造商/商品名称

Millipak®

出口接头直径

1/4 in.

孔径

0.22 μm pore size

配件

outlet stepped hose barb (with bell)

相容性

for use with Milli-Q® EQ 7000
for use with Milli-Q® EQ 7008
for use with Milli-Q® EQ 7016
for use with Milli-Q® IX 7003
for use with Milli-Q® IX 7005
for use with Milli-Q® IX 7010
for use with Milli-Q® IX 7015
for use with Milli-Q® IQ 7000
for use with Milli-Q® IQ 7003
for use with Milli-Q® IQ 7005
for use with Milli-Q® IQ 7010
for use with Milli-Q® IQ 7015

运输

ambient

正在寻找类似产品? 访问 产品对比指南

一般描述

Millipak® Gold 0.22 μm无菌过滤器是由聚醚砜(PES)(聚醚砜)制成的实验室用水耗材,专门用于去除纯化水中的颗粒物和细菌。该过滤器通过0.22 μm的消毒级膜过滤来净化水。
Millipak®过滤器中的膜由锥形孔组成,允许水以较低的压差以较高的流速过滤。将过滤器热封在SAN(苯乙烯-丙烯腈)外壳材料上。谨慎选择外壳材料以及膜和生产工艺,以减少有机和无机提取物的释放。
Millipak® Gold 0.22 μm无菌过滤器适用于Milli-Q® IQ 7000、Milli-Q® IQ 7003/05/10/15、Milli-Q® IX 7003/05/10/15和Milli-Q® EQ 7000/08/16水纯化系统。

应用

提供Milli-Q®纯化水时,Millipak® Gold 0.22 μm无菌过滤器用于各种实验室应用,包括细胞培养和微生物学。

特点和优势

  • 对每个Millipak® Gold 0.22 μm过滤器进行单独检测、密封并交付质量证书。
  • 在 <0.01 cfu/mL when installed and used in a laminar flow hood.
  • Delivers particulate-free water (no particles with size >0.22 μm 处提供无菌水)。
  • 免维护:易于安装和更换。
  • 重新设计了底部尖端,用于安全安装保护罩。
  • 用于RFID与E-POD®或Q-POD®分配器连接的e-Sure标记可实现POD′s触摸屏界面上的完全可追溯性(数据管理)和自动耗材状态监测。

其他说明

这些产品在符合FDA药品生产质量管理规范的工厂生产。
使用说明

  • 生物截留:微生物
  • 作用方式:过滤
  • 应用:实验室一般分析
  • 设计用途:水净化
  • 使用说明:这一产品提供的水经0.22 μm灭菌级膜过滤。请参阅系统设备用户指南“使用系统”部分(在系统包装盒的USB钥匙提供)。
  • 储存声明:干燥储存
  • 处置声明:根据国家、省市和当地适用法规处置。

法律信息

E-POD is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPAK is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany
Q-POD is a registered trademark of Merck KGaA, Darmstadt, Germany

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

  1. How frequently do the various consumables need to be changed?

    The frequency that consumables must be changed depends on the system's usage (treated water volume) and on the consumables themselves (time of usage). In order to ensure the quality of water and your results, the consumables should be replaced when the system alerts you.

  2. What is the consumables delivery time?

    Refer to the consumable's Product page for a first estimation of its expected delivery time and contact customer service for more information.

  3. How are consumables changed?

    To help you to change your system's consumables, several video tutorials are available on our YouTube channel: Milli-Q®System Care Tutorials. For high-flow systems, please keep in mind that all consumable changes must be approved by a 3-digit code that only the person in charge of the system knows.

  4. What is the shelf life for Filter?

    The shelf life is 2 years for all consumables kept in the recommended storage conditions (temperatures from 5 to 30°C; humidity between 10 and 80%). Contact your local representative for more information.

  5. Can I arrange to have my consumables automatically ordered and delivered once a year?

    It's possible to place only one consumable order per year with a specific contract called "Consumable Supply Agreement (CSA)" For further information, contact your local representative or sales contact.

  6. Where can I find data sheets, Certificates of Origin, Certificates of Analysis, and Certificates of Quality?

    Documents and certificates are available in the "Documentation" section on this page. Do not hesitate to contact us if you require further information.

  7. What steps are you taking towards improved sustainability?

    Sustainability is at the heart of our innovations. From reducing water and energy consumption, to minimizing plastic and chemical waste, our dedicated water system engineers are constantly working on new ways to reduce the ecological footprint of our products to better support the sustainability goals we’re all striving towards. For more information, we invite you to review the following brochure and infographic which highlight our efforts and achievements: link. Do not hesitate to contact your local representative for further information.

  8. How can I know which consumables can be used with my system?

    To know which consumables can be used on your system, you can see in the user manual of you system or see it on the following webpage of consumables. All the consumables for each system are indicated.

  9. If I have a final filter that I use only occasionally (e.g., Biopak®) and have another filter (e.g. Millipak®) that I most of the time, can I keep the 'occasional-use' filter for use again at a later time?

    It is not possible to re-use a filter that has been used and then removed because air intake during replacement creates an airlock and blocks water passing through the filter. If you regularly need two different filters, we recommend using two POD dispensers.

  10. Can consumables be opened and refilled?

    Unfortunately, this is not possible because of safety issues and the need to guarantee the quality of consumables and their interior purification components. Our consumables are manufactured in an ISO 9001-certified facility France in agreement with high quality standards.

商品

Discover the importance of water quality in microbiology and its impact on reliable and reproducible results in culture media preparation. Learn about the EN ISO 11133 standard, lab water solutions, and purification technologies recommended for microbiological testing.

了解在采用EN ISO 11133集中纯化水和Milli-Q® IX纯水系统产出的纯水制备微生物培养基及进行性能测试时,如何比较两种水源。测试包括针对李斯特菌和沙门氏菌病原体的专用培养基。