生物来源
mouse
质量水平
抗体形式
purified immunoglobulin
抗体产品类型
primary antibodies
克隆
VP-2E8, monoclonal
种属反应性
human
包装
antibody small pack of 25 μg
技术
flow cytometry: suitable
immunocytochemistry: suitable
immunofluorescence: suitable
immunoprecipitation (IP): suitable
同位素/亚型
IgG1κ
NCBI登记号
UniProt登记号
运输
ambient
靶向翻译后修饰
unmodified
基因信息
human ... EPOR(2057)
一般描述
Erythropoietin receptor (UniProt: P19235, also known as EPO-R) is encoded by the EPOR gene (Gene ID: 2057) in human. EPO-R is a single-pass type I membrane protein that serves as a receptor for erythropoietin. It mediates erythropoietin-induced erythroblast proliferation and differentiation. Upon EPO stimulation, EPO-R dimerizes triggering the JAK2/STAT5 signaling cascade. EPO-R has an extracellular domain (aa 25-250), a transmembrane domain (aa 251-273), and a cytoplasmic domain (aa 274-508). It is synthesized with a signal peptide (aa 1-24) that is cleaved to generate mature EPO-R. Upon stimulation following Erythropoietin (EPO) binding, EPO-R is phosphorylated on C-terminal tyrosine residues by JAK2. The phosphotyrosine motifs are also recruitment sites for several SH2-containing proteins and adapter proteins, which mediate cell proliferation. Phosphorylation on Tyrosine 454 is shown to be essential for PTPN6 interaction, and on Tyrosine 426 for PTPN11 interaction. Tyrosine 426 is also required for SOCS3 binding, however, Tyr-454/Tyr-456 motif is reported to be the preferred binding site. Ubiquitination of EPO-R at Lysine 81 is required for receptor internalization, whereas ubiquitination at Lysine 453 promotes trafficking of activated receptors to the lysosomes for degradation. Defects in EPOR gene are linked to familial erythrocytosis which is characterized by increased serum red blood cell mass, elevated hemoglobin and hematocrit, and hypersensitivity of erythroid progenitors to erythropoietin.
特异性
Clone VP-2E8 recognizes EPO-R in human cells. It targets an epitope within the extracellular domain.
免疫原
A recombinant fragment corresponding to the extracellular domain of human EPO-R.
Epitope: extracellular domain
应用
Anti-EPO-R, clone VP-2E8, Cat. No. MABS1287, is a mouse monoclonal antibody that detects erythropoietin receptor and is tested for use in Flow Cytometry, Immunocytochemistry, Immunofluorescence, and Immunoprecipitation.
Flow Cytometry Analysis: 2 µg/mL from a representative lot detected EPO-R in UT-7 (EPO dependent) cells.
Immunoprecipitation Analysis: A representative lot detected EPO-R in Immunoprecipitation applications (Maxwell, P., et. al. (2015). Br J Haematol. 168(3):429-42).
Immunofluorescence Analysis: A representative lot detected EPO-R in Immunofluorescence applications (Maxwell, P., et. al. (2015). Br J Haematol. 168(3):429-42).
Flow Cytometry Analysis: A representative lot detected EPO-R in Flow Cytometry applications (Maxwell, P., et. al. (2015). Br J Haematol. 168(3):429-42).
Immunoprecipitation Analysis: A representative lot detected EPO-R in Immunoprecipitation applications (Maxwell, P., et. al. (2015). Br J Haematol. 168(3):429-42).
Immunofluorescence Analysis: A representative lot detected EPO-R in Immunofluorescence applications (Maxwell, P., et. al. (2015). Br J Haematol. 168(3):429-42).
Flow Cytometry Analysis: A representative lot detected EPO-R in Flow Cytometry applications (Maxwell, P., et. al. (2015). Br J Haematol. 168(3):429-42).
Research Category
Signaling
Signaling
质量
Evaluated by Immunocytochemistry in starved UT-7 cells.
Immunocytochemistry Analysis: 1:500 dilution of this antibody detected EPO-R in starved UT-7 cells.
Immunocytochemistry Analysis: 1:500 dilution of this antibody detected EPO-R in starved UT-7 cells.
目标描述
55.06 kDa calculated.
外形
Protein G purified
Format: Purified
Purified mouse monoclonal antibody IgG1 in PBS without preservatives.
储存及稳定性
Stable for 1 year at -20°C from date of receipt.
Handling Recommendations: Upon receipt and prior to removing the cap, centrifuge the vial and gently mix the solution. Aliquot into microcentrifuge tubes and store at -20°C. Avoid repeated freeze/thaw cycles, which may damage IgG and affect product performance.
Handling Recommendations: Upon receipt and prior to removing the cap, centrifuge the vial and gently mix the solution. Aliquot into microcentrifuge tubes and store at -20°C. Avoid repeated freeze/thaw cycles, which may damage IgG and affect product performance.
其他说明
Concentration: Please refer to lot specific datasheet.
免责声明
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Not finding the right product?
Try our 产品选型工具.
法规信息
新产品
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门