物料
PVDF
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal
质量水平
管理合规性
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
无菌性
non-sterile
灭菌适用性
autoclavable compatible
产品线
Opticap® XLT 10
特点
hydrophilic
制造商/商品名称
Opticap®
参数
≤13.3 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. inlet pressure (15 psi) at 80 °C
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
技术
sterile filtration: suitable
长度
37.6 cm (14.8 in.)
纯化柱标称长度
10 in. (25 cm)
直径
10.7 cm (4.2 in.)
过滤面积
0.69 m2
入口接头直径
1.5 in.
入口至出口宽度
15.2 cm (6.0 in.)
出口接头直径
1.5 in.
杂质
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
重量萃取物
≤25 mg/capsule
基质
Durapore®
孔径
0.22 μm
输入
sample type liquid
泡点
≥3450 mbar (50 psig), air with water at 23 °C
配件
1/4 in. drain/vent hose barb (with double O-ring Seal)
38 mm (1 1/2 in.) inlet/outlet sanitary flange
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
正在寻找类似产品? 访问 产品对比指南
一般描述
包装
其他说明
- 生物截留:微生物
- 作用机制:过滤(体积排阻)
- 应用:生物处理
- 预期用途:减少或去除微生物/生物负荷
- 使用说明:参见《Durapore® 滤膜过滤器润湿说明》用户手册
- 存储声明:干燥储存
- 处置声明:根据国家、省市和当地适用法规处置。
制备说明
3次高压灭菌循环,每次60 min,126°C;不可在线蒸汽灭菌
分析说明
按ASTM® F838方法进行细菌挑战,样品可截留1 x 10⁷ CFU/cm²以上浓度的缺陷短波单孢菌。
法律信息
免责声明
Not finding the right product?
Try our 产品选型工具.
How frequently do the various consumables need to be changed?
The frequency that consumables must be changed depends on the system's usage (treated water volume) and on the consumables themselves (time of usage). In order to ensure the quality of water and your results, the consumables should be replaced when the system alerts you.
What is the consumables delivery time?
Refer to the consumable's Product page for a first estimation of its expected delivery time and contact customer service for more information.
How are consumables changed?
To help you to change your system's consumables, several video tutorials are available on our YouTube channel: Milli-Q®System Care Tutorials. For high-flow systems, please keep in mind that all consumable changes must be approved by a 3-digit code that only the person in charge of the system knows.
What is the shelf life for Filter?
The shelf life is 2 years for all consumables kept in the recommended storage conditions (temperatures from 5 to 30°C; humidity between 10 and 80%). Contact your local representative for more information.
Can I arrange to have my consumables automatically ordered and delivered once a year?
It's possible to place only one consumable order per year with a specific contract called "Consumable Supply Agreement (CSA)" For further information, contact your local representative or sales contact.
Where can I find data sheets, Certificates of Origin, Certificates of Analysis, and Certificates of Quality?
Documents and certificates are available in the "Documentation" section on this page. Do not hesitate to contact us if you require further information.
What steps are you taking towards improved sustainability?
Sustainability is at the heart of our innovations. From reducing water and energy consumption, to minimizing plastic and chemical waste, our dedicated water system engineers are constantly working on new ways to reduce the ecological footprint of our products to better support the sustainability goals we’re all striving towards. For more information, we invite you to review the following brochure and infographic which highlight our efforts and achievements: link. Do not hesitate to contact your local representative for further information.
How can I know which consumables can be used with my system?
To know which consumables can be used on your system, you can see in the user manual of you system or see it on the following webpage of consumables. All the consumables for each system are indicated.
If I have a final filter that I use only occasionally (e.g., Biopak®) and have another filter (e.g. Millipak®) that I most of the time, can I keep the 'occasional-use' filter for use again at a later time?
It is not possible to re-use a filter that has been used and then removed because air intake during replacement creates an airlock and blocks water passing through the filter. If you regularly need two different filters, we recommend using two POD dispensers.
Can consumables be opened and refilled?
Unfortunately, this is not possible because of safety issues and the need to guarantee the quality of consumables and their interior purification components. Our consumables are manufactured in an ISO 9001-certified facility France in agreement with high quality standards.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门