推荐产品
等级
certified reference material
质量水平
表单
liquid
特点
Snap-N-Spike®/Snap-N-Shoot®
包装
ampule of 1 mL
制造商/商品名称
Cerilliant®
drug control
Narcotic Licence Schedule A (Switzerland); estupefaciente (Spain); Decreto Lei 15/93: Tabela IA (Portugal)
浓度
100 μg/mL in methanol
技术
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
应用
forensics and toxicology
包装形式
single component solution
储存温度
−20°C
SMILES字符串
O=C(OCC)C1(C2=CC=CC=C2)CCNCC1
InChI
1S/C14H19NO2/c1-2-17-13(16)14(8-10-15-11-9-14)12-6-4-3-5-7-12/h3-7,15H,2,8-11H2,1H3
InChI key
QKHMFBKXTNQCTM-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
去甲哌替啶是阿片类镇痛药哌替啶的主要有毒代谢物。 该认证Snap-N-Spike®溶液适用于通过LC-MS/MS、LC/MS 或 GC/MS法进行止痛药处方监测、临床毒理学、尿液药物测试或法医分析。哌替啶是一种具有类似吗啡作用的合成阿片类药物,可用作止痛药。
法律信息
CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany
相关产品
产品编号
说明
价格
警示用语:
Danger
危险分类
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
靶器官
Eyes,Central nervous system
储存分类代码
3 - Flammable liquids
WGK
WGK 2
闪点(°F)
49.5 °F - closed cup
闪点(°C)
9.7 °C - closed cup
法规信息
监管及禁止进口产品
Meperidine in patient-controlled analgesia: a near-fatal mishap.
Anesthesia and analgesia, 76(3), 655-657 (1993-03-01)
Archives of surgery (Chicago, Ill. : 1960), 137(1), 84-88 (2002-01-31)
Intravenous patient-controlled analgesia (IV PCA) meperidine hydrochloride can be used with a reasonable margin of safety. A retrospective review was performed of 355 medical records of patients receiving IV PCA meperidine treatment. Four groups of patients were defined, based on
Toxicology, 95(1-3), 37-44 (1995-01-06)
This study investigated behavioural effects of the toxic pethidine metabolite, norpethidine, in rats and its interactions with reserpine, apomorphine and physostigmine. Following intraperitoneal administration, brain concentrations of norpethidine reached a plateau after 20-40 min and remained elevated for 2 h.
Recognizing normeperidine toxicity.
Nursing, 33(3), 24-24 (2003-03-21)
Yao xue xue bao = Acta pharmaceutica Sinica, 29(2), 116-121 (1994-01-01)
Analytical methods of GC/FID and GC/MS for identification and determination of meperidine, an analgesic drug, and its metabolites were established. The determination of meperidine spiked in urine was shown to have a good linear relationship in the range of 0.1-8.0
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门