跳转至内容
Merck
CN

H-090

1α,25-二羟基维生素D2标准液 溶液

5 μg/mL in ethanol, ampule of 1 mL, certified reference material, Cerilliant®

登录 查看组织和合同定价。

选择尺寸


关于此项目

经验公式(希尔记法):
C28H44O3
化学文摘社编号:
分子量:
428.65
NACRES:
NA.24
UNSPSC Code:
41116107
EC Number:
200-578-6
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

产品名称

1α,25-二羟基维生素D2标准液 溶液, 5 μg/mL in ethanol, ampule of 1 mL, certified reference material, Cerilliant®

InChI key

ZGLHBRQAEXKACO-WQIUIVEWSA-N

InChI

1S/C28H44O3/c1-18(9-10-19(2)27(4,5)31)24-13-14-25-21(8-7-15-28(24,25)6)11-12-22-16-23(29)17-26(30)20(22)3/h9-12,18-19,23-26,29-31H,3,7-8,13-17H2,1-2,4-6H3/b10-9+,21-11+,22-12-

SMILES string

CC(\C=C\C(C)C(C)(C)O)C1CCC2C(\CCCC12C)=C\C=C3\CC(O)CC(O)C3=C

grade

certified reference material

form

liquid

feature

Snap-N-Spike®/Snap-N-Shoot®

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

concentration

5 μg/mL in ethanol

application(s)

clinical testing
clinical testing
clinical testing

format

single component solution

storage temp.

−70°C

Quality Level

General description

准确制备定量引用对于准确评估患者维生素 D 水平非常关键。该认证的加标溶液 ® 适用于研究和临床环境中的关键定量应用,包括:用于制备用于 LC/UV 和 LC-MS/MS 维生素 D 测定的质控品和校准品;作为系统调整/适用性标准;线性验证;内部能力验证;用于 OEM 制备试剂、开发检测试剂盒和仪器 IQ/OQ。稳定、定量的解决方案格式为用户提供了显著的益处,包括节省材料、提高劳动效率和使用方便。保存稳定的Snap-N-Spike®形式可帮助实验室免去痛苦的称重操作,并能在使用前将已知浓度的分析物加入到所选择的基质中。

Legal Information

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

FlameExclamation mark

signalword

Danger

hcodes

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2

存储类别

3 - Flammable liquids

wgk

WGK 1

flash_point_f

57.2 °F - closed cup

flash_point_c

14 °C - closed cup

法规信息

危险化学品
此项目有

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

R A Henik et al.
Journal of the American Veterinary Medical Association, 215(11), 1644-1649 (2003-10-22)
Rickets was diagnosed in a 1-year-old cat with a history of weakness, osteopenia, and recurrent fractures. Processes causing rickets include vitamin D deficiency caused by inadequate, nutrition, lack of exposure to sunlight, defective metabolism of parent vitamin D to active
Rachael M Biancuzzo et al.
The Journal of clinical endocrinology and metabolism, 98(3), 973-979 (2013-02-07)
The purpose of this study was to determine 1,25-dihydroxyvitamin D3 [1,25(OH)2D3] and 1,25-dihydroxyvitamin D2 [1,25(OH)2D2] levels in healthy adults consuming 1000 IU vitamin D2 or vitamin D3 per day for 11 weeks. Blood from 34 healthy male and female adults
Shigeaki Kato et al.
Current opinion in nephrology and hypertension, 16(4), 297-304 (2007-06-15)
Vitamin D has diverse biological actions, and consequently the mechanisms behind how it regulates gene transcription are diverse. Unlike its well described positive effects on gene transcription, little is known about how vitamin D induces transcriptional repression. Vitamin D-induced transcriptional
D R Zimmerman et al.
Archives of biochemistry and biophysics, 392(1), 14-22 (2001-07-27)
Calcitroic acid (1 alpha-hydroxy-23 carboxy-24,25,26,27-tetranorvitamin D(3)) is known to be the major water-soluble metabolite produced during the deactivation of 1 alpha,25-dihydroxyvitamin D(3). This deactivation process involves a series of oxidation reactions at C(24) and C(23) leading to side-chain cleavage and
Richard J Grostern et al.
Archives of ophthalmology (Chicago, Ill. : 1960), 120(5), 607-612 (2002-05-25)
Although calcitriol (1,25-dihydroxycholecalciferol) and vitamin D(2) inhibit retinoblastoma growth in the athymic (nude) mouse xenograft (Y-79 cell line) model of retinoblastoma, they can cause severe toxicity. To examine the toxicity of and dose-dependent response for the inhibition of tumor growth

商品

Using HybridSPE-Phospholipid, Ascentis Express, and Other LC-MS Workflow Components

Novel sample prep technique coupled with the unique selectivity of the Ascentis Express F5 column enables a fast and simplified bioanalytical method for associated vitamin D metabolites.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持