跳转至内容
Merck
CN

H-017

Supelco

m-Hydroxybenzoylecgonine solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C16H19NO5
分子量:
305.33
MDL编号:
UNSPSC代码:
41116107
PubChem化学物质编号:
NACRES:
NA.24

等级

certified reference material

质量水平

形式

liquid

特点

Snap-N-Spike®/Snap-N-Shoot®

包装

ampule of 1 mL

制造商/商品名称

Cerilliant®

drug control

Narcotic Licence Schedule A (Switzerland)

浓度

1.0 mg/mL in methanol

技术

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

应用

forensics and toxicology

格式

single component solution

储存温度

−20°C

SMILES字符串

CN1[C@H]2CC[C@@H]1[C@H]([C@H](C2)OC(=O)c3cccc(O)c3)C(O)=O

InChI

1S/C16H19NO5/c1-17-10-5-6-12(17)14(15(19)20)13(8-10)22-16(21)9-3-2-4-11(18)7-9/h2-4,7,10,12-14,18H,5-6,8H2,1H3,(H,19,20)/t10-,12+,13-,14+/m0/s1

InChI key

XCJJCRPRQYXLRE-AHLTXXRQSA-N

一般描述

m-Hydroxybenzoylecgonine is a urinary metabolite of cocaine and a biomarker for determination of cocaine use. This Certified Spiking Solution® is applicable to use in urine drug testing, clinical toxicology, or forensic analysis by LC-MS/MS or GC/MS.

应用


  • m-Hydroxybenzoylecgonine as a forensic toxicology standard: A study optimized and validated a method for analyzing cocaine and several metabolites including m-Hydroxybenzoylecgonine in human urine via gas chromatography-mass spectrometry, emphasizing its utility in forensic and toxicological applications (Fernández et al., 2019).

  • m-Hydroxybenzoylecgonine for stability studies in toxicology: Research assessed the stability of cocaine metabolites such as m-Hydroxybenzoylecgonine in meconium, contributing to better forensic practices by determining optimal storage conditions (Wu et al., 2017).

  • Accelerated solvent extraction featuring m-Hydroxybenzoylecgonine: A protocol was developed for the extraction of cocaine and its biomarkers from meconium, utilizing m-Hydroxybenzoylecgonine to monitor drug exposure, enhancing the accuracy of drug testing in neonatal care (Mantovani et al., 2014).

法律信息

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

相关产品

产品编号
说明
价格

警示用语:

Danger

危险分类

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

靶器官

Eyes

WGK

WGK 1

闪点(°F)

49.5 °F

闪点(°C)

9.7 °C

法规信息

监管及禁止进口产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

S Pichini et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 820(1), 151-156 (2005-05-04)
A high-performance liquid chromatography (HPLC)-mass spectrometry (MS) assay, already validated for opiates and cocaine in meconium, has been re-applied for determination of m- and p-hydroxybenzoylecgonine, using nalorphine as the internal standard. Methodology included an initial extraction from the matrix by
L M Iwamoto et al.
Drug metabolism and disposition: the biological fate of chemicals, 28(3), 335-338 (2000-02-19)
Recently, meta-hydroxybenzoylecgonine (m-OH BE) was identified by gas chromatography-mass spectroscopy during quantitative analysis for cocaine. Identification of m-OH BE in addition to the routinely identified benzoylecgonine by gas chromatography-mass spectroscopy confirmatory assays may increase detection of cocaine-exposed infants and decrease
Paul P Robandt et al.
Journal of analytical toxicology, 32(8), 577-585 (2008-11-15)
A fully automated system utilizing a liquid handler and an online solid-phase extraction (SPE) device coupled with liquid chromatography-tandem mass spectrometry (LC-MS-MS) was designed to process, detect, and quantify benzoylecgonine (BZE), meta-hydroxybenzoylecgonine (m-OH BZE), para-hydroxybenzoylecgonine (p-OH BZE), and norbenzoylecgonine (nor-BZE)
B W Steele et al.
Journal of analytical toxicology, 17(6), 348-352 (1993-10-01)
Meconium has been reported to be a more suitable specimen than maternal or neonatal urine for detecting fetal exposure to cocaine. In a study comparing various immunoassays with gas chromatography/mass spectrometry (GC/MS), several unexplained discrepancies among the assays were noted.
M A elSohly et al.
Clinics in laboratory medicine, 18(4), 699-704 (1999-01-19)
m-Hydroxybenzoylecgonine (m-OH-BE) and d3-m- hydroxybenzoylecgonine (d3-m-OH-BE) have been synthesized, and a GC/MS procedure with d3-m-OH-BE as internal standard has been developed. Among 24 human urine specimens that were positive for BE, all of them have shown detectable levels of m-OH-BE

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门