InChI key
OLBCVFGFOZPWHH-UHFFFAOYSA-N
InChI
1S/C12H18O/c1-8(2)10-6-5-7-11(9(3)4)12(10)13/h5-9,13H,1-4H3
SMILES string
CC(C)c1cccc(C(C)C)c1O
biological source
synthetic
vapor pressure
5.6 mmHg ( 100 °C)
assay
≥97%
refractive index
n20/D 1.514 (lit.)
bp
256 °C/764 mmHg (lit.)
mp
18 °C (lit.)
density
0.962 g/mL at 25 °C (lit.)
application(s)
flavors and fragrances
Gene Information
human ... CYP1A2(1544), GABRA1(2554)
rat ... Gabra2(29706)
正在寻找类似产品? 访问 产品对比指南
signalword
Warning
hcodes
Hazard Classifications
Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Respiratory system
存储类别
10 - Combustible liquids
wgk
WGK 3
flash_point_f
235.4 °F - closed cup
flash_point_c
113 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
新产品
此项目有
Annette P N Kutter et al.
Anesthesia and analgesia, 121(1), 99-107 (2015-03-06)
In critically ill patients with significant pulmonary hypertension (PH), close perioperative cardiovascular monitoring is mandatory, considering the increased morbidity and mortality in this patient group. Although the pulmonary artery catheter is still the standard for the diagnosis of PH, its
Michael Schwarzl et al.
American journal of physiology. Heart and circulatory physiology, 309(9), H1407-H1418 (2015-09-06)
Heart failure with preserved ejection fraction (HFPEF) evolves with the accumulation of risk factors. Relevant animal models to identify potential therapeutic targets and to test novel therapies for HFPEF are missing. We induced hypertension and hyperlipidemia in landrace pigs (n
Kim van Loon et al.
Anesthesia and analgesia, 119(1), 49-55 (2014-05-20)
Propofol, a short-acting hypnotic drug, is increasingly administered by a diverse group of specialists (e.g., cardiologists, gastroenterologists) during diagnostic and therapeutic procedures. Standard monitoring during sedation comprises continuous pulse oximetry with visual assessment of the patient's breathing pattern. Because undetected
Philippe E Dubois et al.
European journal of anaesthesiology, 31(8), 404-410 (2013-07-26)
Disturbances in the thumb's movement interfere with the functioning of acceleromyography in many clinical settings. The short and light (SL) train-of-four (TOF)-Tube is a new version of a rigid tubular device that was designed to protect the thumb from external
Felix Schlegel et al.
NeuroImage, 116, 40-49 (2015-05-17)
In recent years, the number of functional MRI (fMRI) studies in mice has been rapidly increasing. Technological improvements provide the sensitivity required to match the high demands on spatial and temporal resolution and to analyze fast and small signal components
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持