跳转至内容
Merck
CN

W504904

Sigma-Aldrich

丁酰苯

≥99%

别名:

苯基丙基酮

登录查看公司和协议定价


About This Item

线性分子式:
C6H5COCH2CH2CH3
CAS号:
分子量:
148.20
Beilstein:
508305
EC 号:
MDL编号:
UNSPSC代码:
12164502
PubChem化学物质编号:
Flavis编号:
7.193
NACRES:
NA.21

生物来源

synthetic

质量水平

方案

≥99%

折射率

n20/D 1.520 (lit.)

沸点

228-230 °C (lit.)

mp

11-13 °C (lit.)

密度

1.021 g/mL at 25 °C (lit.)

应用

flavors and fragrances

文件

see Safety & Documentation for available documents

食品过敏原

no known allergens

性状检查

camphoraceous

SMILES字符串

CCCC(=O)c1ccccc1

InChI

1S/C10H12O/c1-2-6-10(11)9-7-4-3-5-8-9/h3-5,7-8H,2,6H2,1H3

InChI key

FFSAXUULYPJSKH-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

储存分类代码

10 - Combustible liquids

WGK

WGK 3

闪点(°F)

190.4 °F

闪点(°C)

88 °C

个人防护装备

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter

法规信息

新产品

从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Fabrice Gritti et al.
Journal of chromatography. A, 1420, 54-65 (2015-10-17)
The impact of the column hardware volume (≃ 1.7 μL) on the optimum reduced plate heights of a series of short 2.1 mm × 50 mm columns (hold-up volume ≃ 80-90 μL) packed with 1.8 μm HSS-T3, 1.7 μm BEH-C18
Fabrice Gritti et al.
Journal of chromatography. A, 1410, 118-128 (2015-08-10)
An original method is proposed for the accurate and reproducible measurement of the time-based dispersion properties of short L< 50cm and narrow rc< 50μm tubes at mobile phase flow rates typically used in very high-pressure liquid chromatography (vHPLC). Such tubes
Ruben De Pauw et al.
Journal of chromatography. A, 1420, 129-134 (2015-10-20)
A new system is proposed for applying fast temperature gradients in liquid chromatography. It consists of a 0.7 mm × 150 mm fused-silica column coated with a 50 μm Nickel-layer, which is connecting with a power source and a temperature
Zsolt Székelyhidi et al.
Bioorganic & medicinal chemistry letters, 15(13), 3241-3246 (2005-06-01)
SR protein-specific kinase-1 (SRPK-1) has been identified as a validated target for hepatitis B virus (HBV). A series of novel tricyclic quinoxaline derivatives was designed and synthesised as potential kinase inhibitory antiviral agents and was found to be active and
Nikola Vaňková et al.
Journal of chromatography. A, 1409, 152-158 (2015-07-29)
The effect of gradient steepness on the kinetic performance limits and peak compression effects has been assessed in gradient mode for the separation of phenol derivatives using columns packed with 2.6μm core-shell particles. The effect of mobile-phase velocity on peak

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门