跳转至内容
Merck
CN

W206105

Sigma-Aldrich

α-戊基肉桂醛

mixture of cis and trans, ≥97%, stabilized, FG

登录查看公司和协议定价

线性分子式:
C6H5CH=C[(CH2)4CH3]CHO
CAS号:
分子量:
202.29
FEMA编号:
2061
欧洲委员会编号:
128
MDL编号:
UNSPSC代码:
12164502
PubChem化学物质编号:
Flavis编号:
5.040
NACRES:
NA.21

生物来源

synthetic

质量水平

等级

FG
Fragrance grade
Halal
Kosher

Agency

follows IFRA guidelines
meets purity specifications of JECFA

管理合规性

EU Regulation 1223/2009
EU Regulation 1334/2008 & 178/2002
FDA 21 CFR 117
FDA 21 CFR 172.515

检测方案

≥97%

包含

BHT as stabilizer

组成

contains IFRA and EU 1223/2009 restricted α-amylcinnamaldehyde

折射率

n20/D 1.557 (lit.)

bp

287-290 °C (lit.)

密度

0.97 g/mL at 25 °C (lit.)

应用

flavors and fragrances

文件

see Safety & Documentation for available documents

食品过敏原

no known allergens

致敏芳香化合物

amyl cinnamal

性状检查

fruity; floral; sweet

SMILES字符串

[H]C(/C(CCCCC)=C/C1=CC=CC=C1)=O

InChI

1S/C14H18O/c1-2-3-5-10-14(12-15)11-13-8-6-4-7-9-13/h4,6-9,11-12H,2-3,5,10H2,1H3/b14-11+

InChI key

HMKKIXGYKWDQSV-SDNWHVSQSA-N

正在寻找类似产品? 访问 产品对比指南

象形图

Exclamation markEnvironment

警示用语:

Warning

危险声明

危险分类

Aquatic Chronic 2 - Skin Sens. 1

WGK

WGK 2

闪点(°F)

294.8 °F

闪点(°C)

146 °C

个人防护装备

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Eiram N Elahi et al.
Chemical research in toxicology, 17(3), 301-310 (2004-03-18)
Skin protein modification (haptenation) is thought to be a key step in the manifestation of sensitization to low molecular mass chemicals (<500 g/mol). For sensitizing chemicals that are not protein reactive, it is hypothesised that metabolic activation can convert such
J D Guin et al.
Journal of the American Academy of Dermatology, 8(1), 76-80 (1983-01-01)
Sensitivity to alpha-amylcinnamic aldehyde (alpha-AcAld) is apparently uncommon, but, like allergy to alpha-amylcinnamic alcohol (alpha-AcAlc), it often accompanies allergy to the perfume in Mycolog cream. Although alpha-AcAlc is a known ingredient, alpha-AcAld is not. However, gas-liquid chromatographic analysis shows alpha-AcAld
Rowe, D.
Perfumer & Flavorist, 30, 20-20 (2005)
S C Rastogi et al.
Contact dermatitis, 38(1), 29-35 (1998-03-21)
Deodorants are one of the most frequently used types of cosmetics and side-effects from them are common. Recent studies relate perfume allergy to this type of product. 73 deodorants were analyzed by gas chromatography--mass spectrometry for the determination of the

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门