跳转至内容
Merck
CN

652458

Sigma-Aldrich

氟化钡

precipitated, 99.95% trace metals basis

别名:

Barium difluoride

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
BaF2
CAS号:
分子量:
175.32
EC 号:
MDL编号:
UNSPSC代码:
12352302
PubChem化学物质编号:
NACRES:
NA.23
方案:
99.95% trace metals basis
表单:
powder

质量水平

方案

99.95% trace metals basis

表单

powder

质量

precipitated

杂质

≤550.0 ppm Trace Metal Analysis

沸点

2260 °C (lit.)

密度

4.830 g/mL at 25 °C
4.89 g/mL at 25 °C (lit.)

SMILES字符串

F[Ba]F

InChI

1S/Ba.2FH/h;2*1H/q+2;;/p-2

InChI key

OYLGJCQECKOTOL-UHFFFAOYSA-L

正在寻找类似产品? 访问 产品对比指南

特点和优势

氟锆酸盐玻璃中的主要玻璃调整剂。

象形图

Skull and crossbones

警示用语:

Danger

危险声明

危险分类

Acute Tox. 3 Oral - Acute Tox. 4 Inhalation

储存分类代码

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 1

闪点(°F)

Not applicable

闪点(°C)

Not applicable

法规信息

危险化学品

从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Jan Kmetko et al.
Physical review letters, 89(18), 186102-186102 (2002-10-26)
In situ synchrotron x-ray diffraction studies of the nucleation of barium fluoride from supersaturated solutions, at fatty-acid monolayer templates, reveal a commensurate relationship between the interfacial lattices of the organic molecules and the inorganic atoms. At the onset of growth
Yasushi Nakano et al.
Medical physics, 29(4), 592-597 (2002-05-07)
Recent advances in the design of photostimulable phosphor (PSP) plates for computed radiography (CR) systems have made it possible to manufacture plates made of BaFI:Eu phosphor material in the cassette form. The image quality of this plate, six BaF(Br,I):Eu plates
H Nanto et al.
Radiation protection dosimetry, 100(1-4), 385-388 (2002-10-18)
BaFI:Eu phosphors are fabricated using a new method of synthesis: liquid phase synthesis, in which the phosphor particles are formed through the association of Ba2+ ions, F-ions and Eu2+ ions in solution. An intense optically stimulated luminescence (OSL) peak at
Jane G Zapka et al.
American journal of preventive medicine, 23(1), 28-35 (2002-07-03)
Developing effective programs to promote colorectal cancer (CRC) screening requires understanding of the effect of healthcare system factors on access to screening and adherence to guidelines. This study assessed the role of insurance status, type of plan, the frequency of
C W van Eijk et al.
Medical progress through technology, 17(3-4), 243-247 (1991-01-01)
A detector has been developed for position sensitive registration of annihilation radiation. The 511 keV gamma rays are detected in a set of BaF2 scintillation crystals coupled to low pressure TMAE-filled photosensitive multi wire chambers. In a first experimental detector

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门