跳转至内容
Merck
CN

601411

Sigma-Aldrich

氟化锂-6Li

95 atom % 6Li, 99% (CP)

登录查看公司和协议定价


About This Item

线性分子式:
6LiF
CAS号:
分子量:
25.01
EC 号:
MDL编号:
UNSPSC代码:
12352302
PubChem化学物质编号:
NACRES:
NA.12

同位素纯度

95 atom % 6Li

质量水平

方案

99% (CP)

表单

solid

mp

842 °C

质量偏移

M-1

SMILES字符串

[6Li+].[F-]

InChI

1S/FH.Li/h1H;/q;+1/p-1/i;1-1

InChI key

PQXKHYXIUOZZFA-HCMAANCNSA-M

正在寻找类似产品? 访问 产品对比指南

包装

这种产品可以散装供应,并可按需包装。有关定价、供货和包装的信息,请联系稳定同位素客户服务

象形图

Skull and crossbonesHealth hazard

警示用语:

Danger

危险声明

危险分类

Acute Tox. 3 Oral - Lact. - Repr. 2

储存分类代码

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

法规信息

危险化学品

从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Paola Francisca Caprile et al.
Health physics, 104(2), 218-223 (2013-01-01)
The characteristics of the thermoluminescence glow curve and dosimetric peak of LiF:Mg,Ti (TLD-100) crystals are studied, with emphasis on the evaluation of the influence of the irradiation dose and heating rate on the dosimetric peak (peak 5) trapping parameters. These
Christian Bernhardsson et al.
Health physics, 103(6), 740-749 (2012-11-01)
Laboratory studies have shown that ordinary household salt (NaCl) exhibits several promising properties for retrospective dosimetry; e.g., a linear dose response and a low detection limit, down to a few mGy or even less. In an attempt to test NaCl
R Takam et al.
Radiation protection dosimetry, 150(1), 22-33 (2011-08-30)
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track
F Bonfigli et al.
Giornale italiano di medicina del lavoro ed ergonomia, 33(3 Suppl), 391-394 (2011-07-01)
Lithium fluoride is a well known material used for dosimetry. In the last years it was proposed and tested also as imaging detector for X-ray microscopy. Optical microscopy represents the oldest and most used imaging technique for medicine and cell
Thorsten Grünheid et al.
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 141(4), 436-443 (2012-04-03)
Cone-beam computed tomography (CBCT) has become a routine imaging modality for many orthodontic clinics. However, questions remain about the amount of radiation patients are exposed to during the scans. This study determined the amounts of radiation potentially absorbed by a

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门