跳转至内容
Merck
CN

564613

Sigma-Aldrich

5-氨基-2-硝基苯甲酸

97%

登录查看公司和协议定价

别名:
2-Nitro-5-aminobenzoic acid, 3-Carboxy-4-nitroaniline, NSC 74455
线性分子式:
H2NC6H3(NO2)CO2H
CAS号:
分子量:
182.13
Beilstein:
2107512
EC 号:
MDL编号:
UNSPSC代码:
12352106
eCl@ss:
32160406
PubChem化学物质编号:
NACRES:
NA.22

质量水平

检测方案

97%

形式

solid

反应适用性

reaction type: solution phase peptide synthesis

mp

236-238 °C (lit.)

应用

peptide synthesis

SMILES字符串

Nc1ccc(c(c1)C(O)=O)[N+]([O-])=O

InChI

1S/C7H6N2O4/c8-4-1-2-6(9(12)13)5(3-4)7(10)11/h1-3H,8H2,(H,10,11)

InChI key

KZZWQCKYLNIOBT-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

应用

Reactant for:
  • Two-component dendritic chain reactions
  • Enzymic activation of hydrophobic self-immolative dendrimers
  • Preparation of insulin receptor tyrosine kinase activator
  • Preparation of polymer-bound diazonium salts using Merrifield resin-bound piperazine

象形图

Flame over circle

警示用语:

Danger

危险声明

危险分类

Ox. Sol. 2

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Gloves, type N95 (US)


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

F Schiele et al.
Clinical chemistry, 33(11), 1978-1982 (1987-11-01)
We describe the process of certification for a gamma-glutamyltransferase reference material (CRM no. 319). Fifteen laboratories participated to this interlaboratory evaluation. All steps of the measurements were controlled in an effort to locate potential sources of variations. In particular, the
Eran Sella et al.
Chemical communications (Cambridge, England), 46(35), 6575-6577 (2010-08-18)
A new dendritic chain reaction probe system was demonstrated to produce exponential signal amplification for the detection of sulfhydryl compounds.
A Balamurugan et al.
Biosensors & bioelectronics, 24(4), 982-986 (2008-09-09)
Herein, we reported for the first time one step procedure for the preparation of cytochrome c (cyt c)-poly (5-amino-2-napthalenesulfonic acid) (PANS) modified glassy carbon electrode by cyclic voltammetrically (CV). Hereafter, we called the above modified electrode as cyt c-PANS electrode.
5-amino-2-nitrobenzoic acid as a reference material for the determination of gamma-GT activity.
S Yamadate et al.
Clinica chimica acta; international journal of clinical chemistry, 160(1), 63-67 (1986-10-15)
Yu Jin Park et al.
Clinical biochemistry, 50(12), 719-725 (2017-03-05)
The use of iodinated contrast media has grown in popularity in the past two decades, but relatively little attention has been paid to the possible interferential effects of contrast media on laboratory test results. Herein, we investigate medical contrast media

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门