跳转至内容
Merck
CN

435139

Sigma-Aldrich

聚(双酚 A 碳酸酯)

melt index 10-12 g/10 min (300°C/1.2kg)

别名:

2,2-双(4-羟基苯基)丙烷-碳酸共聚物, 双酚A碳酸酯聚合物, 双酚A聚碳酸酯, 聚双酚A碳酸酯, 聚碳酸酯

登录查看公司和协议定价


About This Item

CAS号:
MDL编号:
UNSPSC代码:
12162002
PubChem化学物质编号:
NACRES:
NA.23

表单

pellets

质量水平

熔融指数

10-12 g/10 min (300°C/1.2kg)

影响强度

801 J/m (Izod, ASTM D 256, 22.7 °C)

介电常数

2.96, 1 MHz (ASTM D 150)

硬度

118 (Rockwell R, ASTM D 785)

折射率

n20/D 1.586

转变温度

softening point 154 °C (Vicat, rate B, ASTM D 1525)

密度

1.2 g/mL at 25 °C (lit.)

SMILES字符串

CC(C)(c1ccc(O)cc1)c2ccc(O)cc2

InChI

1S/C15H16O2.CH2O3/c1-15(2,11-3-7-13(16)8-4-11)12-5-9-14(17)10-6-12;2-1(3)4/h3-10,16-17H,1-2H3;(H2,2,3,4)

InChI key

XSXWYGABGYBZRM-UHFFFAOYSA-N

基因信息

mouse ... Esr1(13982)
rat ... Ar(24208)

正在寻找类似产品? 访问 产品对比指南

一般描述

服务温度,最高135°C

储存分类代码

11 - Combustible Solids

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Gloves, type N95 (US)


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Brian T Schaefer et al.
Nature communications, 11(1), 4163-4163 (2020-08-21)
Solid-state magnetic field sensors are important for applications in commercial electronics and fundamental materials research. Most magnetic field sensors function in a limited range of temperature and magnetic field, but Hall sensors in principle operate over a broad range of
Vianney Souplet et al.
Methods in molecular biology (Clifton, N.J.), 570, 287-297 (2009-08-04)
Microarrays are frequently prepared on microscope glass slides. However, glass substrates can break or cut and thus can lead to the contamination of the manipulator during the analysis of biological samples. Alternately, bisphenol A polycarbonate (PC) is shock-resistant and, in
A study on the effect of gamma radiation sterilization of polycarbonate (LMW).
M Jayabalan et al.
Biomedical sciences instrumentation, 23, 149-153 (1987-01-01)
L Coulier et al.
Journal of chromatography. A, 1070(1-2), 79-87 (2005-05-03)
Size exclusion chromatography (SEC), gradient polymer elution chromatography (GPEC) and liquid chromatography at critical conditions (LC-CC) have been developed and applied to observe chemical changes in poly(bisphenol A)carbonate (PC) due to hydrolytic degradation. Especially LC-CC appeared to be very successful
Georgia P Tsintzou et al.
Journal of hazardous materials, 241-242, 137-145 (2012-10-10)
The various and widespread uses of polycarbonate (PC) polymers require a meaningful and environmentally friendly disposal method. In this study, depolymerisation of polycarbonate with water in a microwave reactor is suggested as a recycling method. Hydrolysis was investigated in an

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门