跳转至内容
Merck
CN

427888

Sigma-Aldrich

聚丙烯

Isotactic, average Mw ~250,000, average Mn ~67,000

登录查看公司和协议定价

别名:
PP, polypropene
线性分子式:
[CH2CH(CH3)]n
CAS号:
MDL编号:
UNSPSC代码:
12162002
PubChem化学物质编号:
NACRES:
NA.23

质量水平

形式

beads

熔融指数

12 g/10 min (230°C/2.16kg)

分子量

average Mn ~67,000
average Mw ~250,000

硬度

100 (Rockwell R, ASTM D 785-A)

转变温度

Tm 160-165 °C

密度

0.9 g/mL at 25 °C (lit.)

应用

battery manufacturing

SMILES字符串

CC=C

InChI

1S/C22H42O3/c1-2-3-4-5-11-14-17-20-21(25-20)18-15-12-9-7-6-8-10-13-16-19-22(23)24/h20-21H,2-19H2,1H3,(H,23,24)/t20-,21+/m1/s1

InChI key

NSYDMBURIUSUDH-RTWAWAEBSA-N

正在寻找类似产品? 访问 产品对比指南

应用

可与柱塞式注塑机和螺杆式注塑机配合使用。用于汽车、家庭用品、普通注塑制品以及复丝和单丝纤维。

特点和优势

高刚度,良好的耐溶剂和化学品性质。抗环境应力开裂。比聚乙烯更易于氧化。

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Gloves, type N95 (US)


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

R Yan et al.
Food microbiology, 87, 103354-103354 (2020-01-18)
Viruses are transmissible via their interaction with contact surfaces of food containers or tools. This study evaluated the recoveries of MS2 coliphage, a virus surrogate, from polypropylene (PP), polyvinyl chloride (PVC), polyethylene (PE), and glass (borosilicate and soda lime), as
G Imanidis et al.
European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V, 47(3), 283-287 (1999-06-26)
The possibility to control the release rate of salbutamol through the hydrophobic Celgard 2500 polypropylene membrane by varying the composition and the viscosity of hydrophilic drug vehicles was investigated. The use of the polypropylene membrane as a control membrane for
Simon J Gallagher et al.
Journal of drug targeting, 11(6), 373-379 (2003-12-12)
The aim of this study was to test the hypothesis that the most appropriate model for studying the diffusional release of an active from a topical formulation is one in which the membrane offers minimal resistance to release and involves
[Procedure for membrane oxygenation of blood over hydrophilic polymer membranes].
H Körber et al.
Biomedizinische Technik. Biomedical engineering, 43 Suppl, 338-340 (1998-12-22)
F Cassiola et al.
Artificial organs, 24(3), 168-173 (2000-04-12)
The introduction of microporous polypropylene hollow fibers in recent years has brought considerable advances to blood oxygenators. However, lifetime and assembly problems are still unresolved. In this work we tried to rate the oxygen permeation velocity by turning the fibers

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门