描述
coefficient of friction 0.53 Dynamic, p=110 lbs,
velocity=0.08-0.35 cm/sec
形式
pellets
熔融指数
11 g/10 min (279°C/49 newton)
硬度
50-58 (Rockwell R, ASTM D 785)
折射率
n20/D 1.3
转变温度
brittleness temperature -125 °C (ASTM D 746)
Tm 250-270 °C (ASTM D 3418)
密度
1.73 g/mL at 25 °C (lit.)
SMILES字符串
C=C.F\C(F)=C(\F)F
InChI
1S/C2F4.C2H4/c3-1(4)2(5)6;1-2/h;1-2H2
InChI key
QHSJIZLJUFMIFP-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
应用
用于注塑和挤出漆包线漆膜、管、薄膜和单丝。
特点和优势
机械性能比全氟聚合物如 PTFE 和 PFA 更为优越。在广泛的温度范围内具有绝佳的性能,并且在广泛的温度和频率范围内具有良好的电绝缘性。
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
Journal of biomedical materials research, 29(1), 59-63 (1995-01-01)
The release behavior of typical commercial tissue expanders has been examined by carrying out two kinds of experiments: 1) Determination of chemical nature and its modification after in vivo use by X-ray photoelectron spectroscopy for chemical analysis. This study has
Risk analysis : an official publication of the Society for Risk Analysis, 18(4), 471-510 (1998-10-17)
This paper investigates electrical overheating events aboard a habitable spacecraft. The wire insulation involved in these failures plays a major role in the entire event scenario from threat development to detection and damage assessment. Ideally, if models of wire overheating
The Biochemical journal, 217(1), 135-143 (1984-01-01)
A modification to the competitive labelling procedure of Duggleby and Kaplan [(1975) Biochemistry 14, 5168-5175] was used to study the reactivity of the N-termini, lysine, histidine and tyrosine groups of insulin over the concentration range 1 X 10(-3)-1 X 10(-7)M.
Dental materials : official publication of the Academy of Dental Materials, 18(6), 479-485 (2002-07-06)
This pilot study was conducted to explore selected commercially-available thermoplastic composites that potentially had physical properties superior to currently available dental systems for restoring esthetic posterior crowns. Polyurethane, polycarbonate, and poly(ethylene/tetrafluoroethylene) (ETFE) composites and unfilled polyurethane specimens were injection molded
Frontiers in bioscience : a journal and virtual library, 9, 1412-1421 (2004-02-24)
Pioneers in the field of small diameter graft development sought to promote graft endothelialization and, thereby, increase patency by transplanting a varying degree of autologous endothelial cells onto vascular grafts prior to implantation. This process has become known as endothelial
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门