登录 查看组织和合同定价。
选择尺寸
关于此项目
线性分子式:
NH4B(C6H5)4
化学文摘社编号:
分子量:
337.27
Beilstein/REAXYS Number:
3799683
UNSPSC Code:
12161600
NACRES:
NA.22
PubChem Substance ID:
MDL number:
产品名称
四苯基硼酸铵, 99%
InChI
1S/C24H20B.H3N/c1-5-13-21(14-6-1)25(22-15-7-2-8-16-22,23-17-9-3-10-18-23)24-19-11-4-12-20-24;/h1-20H;1H3/q-1;/p+1
SMILES string
[H][N+]([H])([H])[H].c1ccc(cc1)[B-](c2ccccc2)(c3ccccc3)c4ccccc4
InChI key
ZWFYDLYRTYMBIL-UHFFFAOYSA-O
assay
99%
reaction suitability
core: boron
reagent type: catalyst
mp
220 °C (dec.) (lit.)
Quality Level
正在寻找类似产品? 访问 产品对比指南
signalword
Warning
hcodes
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Respiratory system
存储类别
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
dust mask type N95 (US), Eyeshields, Gloves
S I M Zayed et al.
Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 26(1), 45-49 (2010-01-13)
The construction and electrochemical response characteristics of two new polyvinyl chloride (PVC) membrane sensors for the determination of sibutramine hydrochloride were described. The sensors are based on the ion association complexes of sibutramine with sodium tetraphenylborate (NaTPB) or phosphotungstic acid
Beata Paczosa-Bator et al.
Talanta, 81(3), 1003-1009 (2010-03-20)
This paper focuses on the quantitative determination of the loss of the components from plastic membranes of ion-selective electrodes (ISEs) during contact with aqueous bathing solutions. The leaching processes, which affect the ISE responses, are rarely characterized by independent methods.
Mirela Samardžić et al.
Talanta, 83(3), 789-794 (2010-12-15)
A sensitive potentiometric surfactant sensor based on a highly lipophilic 1,3-didecyl-2-methyl-imidazolium cation and a tetraphenylborate (TPB) antagonist ion was used as the end-point detector in ion-pair potentiometric surfactant titrations using sodium TPB as a titrant. Several analytical and technical grade
Hajime Katano et al.
Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 28(12), 1153-1157 (2012-12-13)
A biopolymer ε-poly-L-lysine (εPL) exists as a fully protonated form (εPLH(n+)) in solutions at pH < 4. Around pH 3.5, at which the tetraphenylborate (TPB(-)) anion is not decomposed immediately, the εPLH(n+) cation associates with the TPB(-) anion to form
D C Kapsimali et al.
Talanta, 80(3), 1311-1317 (2009-12-17)
Two different derivatizing reagents were tested for the development of a fast and sensitive method for the determination of selenites (Se(IV)) in human urine. The reagents were sodium tetraethylborate (NaBEt(4)) and tetraphenylborate (NaBPh(4)), respectively, and the procedure is based on
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持