推荐产品
蒸汽压
<0.01 mmHg ( 537.2 °C)
质量水平
方案
≥99.9% trace metals basis
表单
wire
自燃温度
572 °F
电阻率
13.5 μΩ-cm, 20°C
直径
0.5 mm
沸点
5425 °C (lit.)
mp
2996 °C (lit.)
密度
16.69 g/cm3 (lit.)
SMILES字符串
[Ta]
InChI
1S/Ta
InChI key
GUVRBAGPIYLISA-UHFFFAOYSA-N
数量
3.3g = 1m;33g = 10m
储存分类代码
11 - Combustible Solids
WGK
nwg
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
法规信息
新产品
Water environment research : a research publication of the Water Environment Federation, 84(12), 2115-2122 (2013-01-25)
Tantalum hydroxide exhibits the ability for the removal of phosphate from aqueous solution. The kinetic study, adsorption isotherm, thermodynamic study, desorption, and foreign anions effect were examined in batch experiments. The kinetic process was very well described by a pseudo-second-order
Clinical orthopaedics and related research, 471(7), 2238-2244 (2013-01-22)
One cross-linked polyethylene (XLPE) liner is manufactured using a lower dose of radiation, 5 Mrad, which may result in less cross-linking. The reported in vivo wear rate of this XLPE liner in patients undergoing THA has varied, and has included
Clinical orthopaedics and related research, 470(11), 3156-3163 (2012-09-25)
Stabilization of a pelvic discontinuity with a posterior column plate with or without an associated acetabular cage sometimes results in persistent micromotion across the discontinuity with late fatigue failure and component loosening. Acetabular distraction offers an alternative technique for reconstruction
Journal of shoulder and elbow surgery, 22(4), 535-541 (2012-09-11)
Aseptic loosening of all-polyethylene glenoid components remains a limiting factor in achieving long-term implant survival in total shoulder arthroplasty (TSA). This study prospectively evaluated the functional and radiographic outcomes of patients undergoing TSA with a novel, porous, tantalum-backed glenoid component
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 45(2), 141-144 (2013-01-02)
Type 1 endoleaks following endovascular aortic aneurysm repair are associated with poor outcomes and re-intervention is recommended as soon as possible after diagnosis. When standard endovascular or surgical treatment options are unsuitable due to severe co-morbidity or adverse anatomic factors
商品
Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门