跳转至内容
Merck
CN

280577

Sigma-Aldrich

顺-13-二十二碳烯酸

别名:

芥酸酰胺

登录查看公司和协议定价


About This Item

线性分子式:
CH3(CH2)7CH=CH(CH2)11CONH2
CAS号:
分子量:
337.58
EC 号:
MDL编号:
UNSPSC代码:
12352100
PubChem化学物质编号:
NACRES:
NA.22

表单

beads

质量水平

组成

erucamide, >85%

mp

79-81 °C (lit.)

官能团

amide

储存温度

−20°C

SMILES字符串

[H]\C(CCCCCCCC)=C(/[H])CCCCCCCCCCCC(N)=O

InChI

1S/C22H43NO/c1-2-3-4-5-6-7-8-9-10-11-12-13-14-15-16-17-18-19-20-21-22(23)24/h9-10H,2-8,11-21H2,1H3,(H2,23,24)/b10-9-

InChI key

UAUDZVJPLUQNMU-KTKRTIGZSA-N

正在寻找类似产品? 访问 产品对比指南

应用

顺式-13-多科舍诺酰胺(芥酸酰胺)用作:
  • 气相色谱/质谱法测定聚乙烯包装薄膜中脂肪酸酰胺的标准
  • 用于聚合物的增滑剂,以降低它们的摩擦系数并使薄膜更容易处理

储存分类代码

11 - Combustible Solids

WGK

WGK 1

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Gloves, type ABEK (EN14387) respirator filter


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Gang Lv et al.
Journal of chromatography. A, 1216(48), 8545-8548 (2009-10-28)
A new method for determination of fatty acid amides in polyethylene packaging film was developed using gas chromatography/mass spectrometry (GC/MS). Liquid extraction, Soxhlet extraction ultrasonic-assisted extraction and pressurized solvent extraction (PSE) methods were compared and the results showed that pressurized
John Watson et al.
Journal of biomolecular screening, 14(5), 566-572 (2009-05-28)
Disposable plastic labware is ubiquitous in contemporary pharmaceutical research laboratories. Plastic labware is routinely used for chemical compound storage and during automated liquid-handling processes that support assay development, high-throughput screening, structure-activity determinations, and liability profiling. However, there is little information
Alvaro Garrido-López et al.
Journal of chromatography. A, 1150(1-2), 178-182 (2006-12-13)
Polymers require the use of some slip agents, such as oleamide and erucamide, in order to reduce their friction coefficient and to make films easier to handle. In this communication, three analytical methods consisting in pressurized liquid extraction (PLE) and
Alvaro Garrido-López et al.
Journal of chromatography. A, 1124(1-2), 51-56 (2006-05-24)
A pressurized fluid extraction (PFE) and gas chromatography-flame ionization detection (GC-FID) method is proposed to determine the slip agents in polyethylene (PE) films. The study of PFE variables was performed using a fractional factorial design (FFD) for screening and a
Shilpa Y Sankhe et al.
Applied spectroscopy, 57(1), 37-43 (2003-11-13)
The diffusion of additives in thick (approximately 500 microns) single layer and multilayer films has been characterized using FT-IR microspectroscopy. The objective of this research was to investigate additive migration and concentration profiles in coextruded multilayer films of industrially relevant

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门