推荐产品
蒸汽压
<0.01 mmHg ( 537.2 °C)
质量水平
方案
≥99.9% trace metals basis
表单
foil
自燃温度
572 °F
电阻率
13.5 μΩ-cm, 20°C
厚度
0.25 mm
沸点
5425 °C (lit.)
mp
2996 °C (lit.)
密度
16.69 g/cm3 (lit.)
SMILES字符串
[Ta]
InChI
1S/Ta
InChI key
GUVRBAGPIYLISA-UHFFFAOYSA-N
一般描述
The structure of tantalum is body centered cubic (BCC) metal. It is a refractory metal; stable up to very high temperatures. Tantalum is ductile at room temperature and moderately ductile at cryogenic temperatures. Compton profile of highly pure thin elemental foil of tantalum was investigated using IGP type coaxial photon detector.1
数量
50x50 mm (approximately 10.4 g)
100x100 mm (approximately 41.6 g)
100x100 mm (approximately 41.6 g)
储存分类代码
11 - Combustible Solids
WGK
nwg
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
法规信息
新产品
The Morphology of Tensile Failure in Tantalum
Boyce BL, et al.
Metallurgical and Materials Transactions A: Physical Metallurgy and Materials Science, 44(10), 4567-4580 (2013)
A M Ashmore et al.
Journal of biomechanics, 45(16), 2931-2934 (2012-10-13)
Interest in soft tissue RadioStereometric Analysis (RSA) is rising. Previous studies have attempted to use this technique to analyse anterior cruciate ligament (ACL) graft constructs, and more recently, the movement of soft tissue as a precursor to RSA follow up
Frédéric Clarençon et al.
Journal of neurosurgery. Spine, 18(6), 606-610 (2013-04-23)
Presurgical devascularization of hypervascular spinal metastases has been shown to be effective in preventing major blood loss during open surgery. Most often, embolization can be performed using polyvinyl alcohol (PVA) microparticles. However, in some cases, the close relationship between the
Re: Fernandez-Fairen M, Murcia A, Torres A, et al. Is anterior cervical fusion with a porous tantalum implant a cost-effective method to treat cervical disc disease with radiculopathy? Spine 2012; 37:1734–41.
Robert A Beatty
Spine, 38(4), 369-369 (2012-10-13)
Biomimetic oxygen activation by MoS2/Ta3N5 nanocomposites for selective aerobic oxidation.
Qingsheng Gao et al.
Angewandte Chemie (International ed. in English), 51(47), 11740-11744 (2012-10-17)
商品
Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门