跳转至内容
Merck
CN

229962

Sigma-Aldrich

氯化铊(I)

99.999% trace metals basis

登录查看公司和协议定价

别名:
氯化亚铊
线性分子式:
TlCl
CAS号:
分子量:
239.84
EC 号:
MDL编号:
UNSPSC代码:
12352302
PubChem化学物质编号:
NACRES:
NA.23

蒸汽压

10 mmHg ( 517 °C)

质量水平

检测方案

99.999% trace metals basis

形式

powder

反应适用性

reagent type: catalyst
core: thallium

杂质

≤20.0 ppm Trace Metal Analysis

bp

720 °C/1 atm (lit.)

mp

430 °C (lit.)

溶解性

ethanol: insoluble(lit.)

密度

7 g/mL at 25 °C (lit.)

SMILES字符串

Cl[Tl]

InChI

1S/ClH.Tl/h1H;/q;+1/p-1

InChI key

GBECUEIQVRDUKB-UHFFFAOYSA-M

正在寻找类似产品? 访问 产品对比指南

应用

用于制备双核笼状配合物(铊-环磷腈),该配合物具有令人感兴趣的金属间相互作用。

警示用语:

Danger

危险分类

Acute Tox. 2 Inhalation - Acute Tox. 2 Oral - Aquatic Chronic 2 - STOT RE 2

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges

法规信息

新产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Amir Sh Saljooghi et al.
Journal of applied toxicology : JAT, 31(2), 139-143 (2010-08-06)
The present research aimed to characterize the potential efficiency of deferasirox in removing thallium after its administration for 30 days following two dose levels of 20 and 160 μm of thallium (III) chloride to male Wistar rats every day. After thallium
Shigenori Nagata et al.
Diagnostic pathology, 5, 34-34 (2010-06-01)
A case of benign mixed tumor of the soft tissue in a 64-year-old Japanese male is presented. He noticed a painless, elastic hard mass sized 3 cm in the right knee, which gradually grew larger and harder in the last
A Clouvas et al.
Radiation protection dosimetry, 152(4), 414-417 (2012-05-23)
In the current study, the time-dependent retention of (201)Tl-thallous chloride (111 MBq) was measured in a 56-y-old man undergoing myocardial perfusion imaging. For 23 d following the (201)Tl injection, total-body retained activity was measured by (i) in situ gamma spectrometry
Yoshimitsu Fukushima et al.
Annals of nuclear medicine, 22(5), 363-369 (2008-07-05)
Earlier studies suggested that elevated cardiac troponin T (cTnT) might be useful for detecting less severe types of myocardial injury (i.e., non-ST segment elevation myocardial infarction). The objective of this study is to elucidate the usefulness of (201)thallous chloride ((201)TlCl)
Yasushi Yamamoto et al.
Annals of nuclear medicine, 26(8), 634-643 (2012-07-11)
The degree of myocardial technetium-(99m)-pyrophosphate ((99m)Tc-PYP) accumulation in cardiac amyloidosis is conventionally evaluated by the PYP score. This method involves qualitative visual evaluation on two-dimensional images. Here, we performed three-dimensional quantitative analysis using software developed in our laboratory. We performed

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门