所有图片(2)
About This Item
线性分子式:
(CH2CH[CH2CH(CH3)2])n
CAS号:
MDL编号:
UNSPSC代码:
12162002
PubChem化学物质编号:
NACRES:
NA.23
推荐产品
质量水平
表单
solid
熔融指数
26 g/10 min (260°C/5kg)
影响强度
3 kg.cm/cm2 (Izod, ASTM D 256)
介电常数
2.12, 100 MHz (ASTM D 150)
硬度
80 (Rockwell R, ASTM D 758)
折射率
n20/D 1.463
mp
235 °C
转变温度
softening point 178 °C (Vicat, ASTM D 1525)
密度
0.835 g/mL at 25 °C
SMILES字符串
CC(C)CC=C
InChI
1S/C6H12/c1-4-5-6(2)3/h4,6H,1,5H2,2-3H3
InChI key
WSSSPWUEQFSQQG-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
应用
用于微波炉和传统烤箱的纸制食品容器涂层。用于食品和合成革的防粘涂层。用于模制医疗实验室器具。用于装饰性层压板和印刷电路板的薄膜。
特点和优势
极低的比重、极高的透明性以及抗氧化性,并且易于应力开裂。绝佳的电绝缘体。
外形
晶体,全同立构体。
储存分类代码
11 - Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
Elimination of sevoflurane is reduced in plasma-tight compared to conventional membrane oxygenators.
C Prasser et al.
European journal of anaesthesiology, 25(2), 152-157 (2007-07-28)
It has been demonstrated that volatile anaesthetics have cardioprotective properties during open-heart procedures, especially when administered continuously. European Council Directive 93/42/EEC concerning medical devices bans the supplementary incorporation of anaesthetic vaporizers in the bypass circuit. Since the uptake of volatile
Sang-Chul Shin et al.
International journal of pharmaceutics, 235(1-2), 141-147 (2002-03-07)
Triprolidine-containing matrix was fabricated with poly(4-methyl-1-pentene) (TPX) polymer to control the release of the drug. Effect of penetration enhancer and stripping of skin on the permeation of triprolidine through the excised mouse skin was studied. Penetrating enhancers showed the increased
LaNetra M Clayton et al.
Journal of nanoscience and nanotechnology, 6(8), 2520-2524 (2006-10-14)
Poly(4-methyl-1-pentene), PMP, a high melting polymer composed of hydrogen and carbon, has the potential to become an alternative to polyethylene (PE) as shielding material against Galactic Cosmic Radiation (GCR). PMP exhibits higher thermal stability than PE and is transparent in
Ayano Chiba et al.
Physical review. E, Statistical, nonlinear, and soft matter physics, 85(2 Pt 1), 021807-021807 (2012-04-03)
High-pressure in situ x-ray diffraction and specific-volume measurements on isotactic poly(4-methyl-1-pentene) melt have uncovered abrupt changes in the pressure dependence of microscopic structure as well as that of macroscopic density. The first sharp diffraction peak of the polymer melt, which
Michael T Demko et al.
ACS nano, 6(8), 6890-6896 (2012-07-18)
Soft lithography methods are emerging as useful tools for high-resolution, three-dimensional patterning of polymers and nanoparticles. However, the low Young's modulus of the standard template material, poly(dimethylsiloxane) (PDMS), limits attainable resolution, fidelity, and alignment capability. While much research has been
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门