InChI key
IYZPEGVSBUNMBE-UHFFFAOYSA-N
InChI
1S/C32H32N2O12/c1-17-7-21(9-19(29(17)43)11-33(13-25(35)36)14-26(37)38)32(24-6-4-3-5-23(24)31(45)46-32)22-8-18(2)30(44)20(10-22)12-34(15-27(39)40)16-28(41)42/h3-10,43-44H,11-16H2,1-2H3,(H,35,36)(H,37,38)(H,39,40)(H,41,42)
SMILES string
Cc1cc(cc(CN(CC(O)=O)CC(O)=O)c1O)C2(OC(=O)c3ccccc23)c4cc(C)c(O)c(CN(CC(O)=O)CC(O)=O)c4
technique(s)
titration: suitable
mp
181-185 °C (dec.) (lit.)
λmax
377 nm (2nd), 575 nm
存储类别
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
法规信息
新产品
此项目有
C M Corns
Annals of clinical biochemistry, 27 ( Pt 2), 152-155 (1990-03-01)
The spectral interference caused by haemoglobin in the calcium-cresolphthalein complexone reaction was investigated. The results show that the nature of the haemoglobin derivative in the reaction mixture influences the degree of interference; in turn, the derivative formed depends on the
B Aghabeigi et al.
International journal of oral and maxillofacial surgery, 31(6), 646-649 (2003-01-11)
Saline aspirates have been commonly used in the biochemical investigations of temporomandibular joint (TMJ) pathology. However, due to presence of adhesions in the diseased temporomandibular joint, full equilibration between the injected saline and the synovial fluid may not be achieved
D H Patterson et al.
Journal of chromatography. A, 662(2), 389-395 (1994-02-25)
Electrophoretically mediated microanalysis (EMMA) was used for the determination of calcium. The faster analyte zone containing the calcium was injected spatially behind a slower zone of o-cresolphthalein complexone in a capillary electrophoresis based system. Upon application of the electric field
James H Wible et al.
Radiology, 233(1), 158-164 (2004-09-30)
To measure serum calcium concentration with three different analytic methods after administration of gadoversetamide and three other gadolinium chelates in dogs. Six dogs were injected with 0.1-, 0.3-, 1.0-, and 3.0-mmol/kg doses of gadoversetamide; 1.0-mmol/kg doses of gadodiamide, gadopentetate, and
A E Hartmann et al.
American journal of clinical pathology, 82(2), 182-187 (1984-08-01)
An automated calcium method based on o-cresolphthalein complexone chemistry and designed to be used in conjunction with the Beckman ASTRA systems (Beckman Instruments, Inc., Brea, CA) was evaluated. Day-to-day reproducibility studies yielded coefficients of variation ranging from 1.2 to 3.1%.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持