跳转至内容
Merck
CN

183997

Sigma-Aldrich

三己胺

96%

登录查看公司和协议定价


About This Item

线性分子式:
[CH3(CH2)5]3N
CAS号:
分子量:
269.51
Beilstein:
1755828
EC 号:
MDL编号:
UNSPSC代码:
12352100
PubChem化学物质编号:
NACRES:
NA.22

蒸汽密度

9.3 (vs air)

蒸汽压

<1 mmHg ( 20 °C)

方案

96%

表单

liquid

折射率

n20/D 1.442 (lit.)

沸点

150-159 °C/12 mmHg (lit.)
263-265 °C (lit.)

密度

0.794 g/mL at 25 °C (lit.)

官能团

amine

SMILES字符串

CCCCCCN(CCCCCC)CCCCCC

InChI

1S/C18H39N/c1-4-7-10-13-16-19(17-14-11-8-5-2)18-15-12-9-6-3/h4-18H2,1-3H3

InChI key

DIAIBWNEUYXDNL-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

应用

在从大肠埃希菌发酵液中分离纯化琥珀酸时,使用三己胺作为萃取剂 。它被作为内标物用于离子迁移光谱法筛选设计药物的人发样品。将其用于小直径氧化锌纳米棒的合成

象形图

Exclamation markEnvironment

警示用语:

Warning

危险分类

Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

靶器官

Respiratory system

储存分类代码

10 - Combustible liquids

WGK

WGK 3

闪点(°F)

235.4 °F - closed cup

闪点(°C)

113 °C - closed cup

个人防护装备

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

T Keller et al.
Forensic science international, 94(1-2), 55-63 (1998-07-22)
Since its inception in the early 1970s under the name plasma chromatography, ion mobility spectrometry (IMS) has undergone great changes. It is now utilized more and more in forensic science laboratories where it is used to detect explosives and environmental
Tanja Kurzrock et al.
Biotechnology progress, 27(6), 1623-1628 (2012-01-13)
Biotechnologically produced succinic acid has the potential to displace maleic acid and its uses. Therefore, it is of high interest for the chemical, pharmaceutical, and food industry.In addition to optimized production strains and fermentation processes, an efficient separation of succinic
Louwanda Lakiss et al.
Chemphyschem : a European journal of chemical physics and physical chemistry, 21(16), 1873-1881 (2020-03-17)
We outline two methodologies to selectively characterize the Brønsted acidity of the external surface of FAU-type zeolites by IR and NMR spectroscopy of adsorbed basic probe molecules. The challenge and goal are to develop reliable and quantitative IR and NMR
Diameter control and photoluminescence of ZnO nanorods from trialkylamines.
Andelman T, et al.
Journal of Nanomaterials, 2007 (2007)
Erica L Bakota et al.
Rapid communications in mass spectrometry : RCM, 34(5), e8608-e8608 (2019-11-11)
While liquid chromatography/high-resolution mass spectrometry (LC/HRMS) is a versatile analytical technique, it is also sensitive to trace impurities. These impurities may come from a variety of sources, including reagents, solvents, and the sample matrix itself. Impurities in reagents may become

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门