跳转至内容
Merck
CN

183725

Sigma-Aldrich

4-(咪唑-1-基)苯酚

97%

别名:

1-(4-羟基苯基)咪唑

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C9H8N2O
CAS号:
分子量:
160.17
EC 号:
MDL编号:
UNSPSC代码:
12352005
PubChem化学物质编号:
NACRES:
NA.22

质量水平

检测方案

97%

形式

powder

mp

204-206 °C (lit.)

SMILES字符串

Oc1ccc(cc1)-n2ccnc2

InChI

1S/C9H8N2O/c12-9-3-1-8(2-4-9)11-6-5-10-7-11/h1-7,12H

InChI key

CYKCUAPYWQDIKR-UHFFFAOYSA-N

应用

4-(咪唑-1-基)苯酚通过基于 酿酒酵母 - Lac - Z 报告基因分析 用于评价酚类外源性雌激素的雌激素活性。

象形图

Exclamation mark

警示用语:

Warning

危险声明

危险分类

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

靶器官

Respiratory system

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

dust mask type N95 (US), Eyeshields, Gloves


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Effect of substituent size and dimensionality on potency of phenolic xenoestrogens evaluated with a recombinant yeast assay.
Schultz TW, et al.
Environmental Toxicology and Chemistry / Setac, 19(11), 2637-2642 (2000)
Wan Qiu Xia et al.
Analytical biochemistry, 554, 9-15 (2018-05-29)
In this study, a molecularly imprinted polymer based chemiluminescence array capable of simultaneous determining phenothiazines and benzodiazepines was first reported. Two polymers were coated in different wells of the conventional 96-well microtiter plate as the recognition reagents, and the added
Marimuthu Senthilkumaran et al.
Journal of fluorescence, 27(6), 2159-2168 (2017-09-10)
The interaction of n-(4-hydroxyphenyl)-imidazole with p-sulfonatocalix[4]arene is studied using fluorescence technique. The quenching of fluorescence intensity explains the efficiency of binding via binding constant and quenching constant. The excited state lifetime of n-(4-hydroxyphenyl)-imidazole is decreased upon interaction with p-sulfonatocalix[4]arene. The
Yi Cai et al.
Food chemistry, 280, 103-109 (2019-01-16)
In this study, a molecularly imprinted polymer capable of recognizing 8 benzimidazoles was first synthesized. The computation simulation showed that the shape and size of used template were the main factors influencing its recognition ability. Then the polymer was used
Lili Wang et al.
PloS one, 14(10), e0223096-e0223096 (2019-10-11)
Activated platelets release adenosine trisphosphate (ATP) and bioluminescence analysis of ATP release is usually used to monitor activation of platelets induced by various stimulants. However, bioluminescence analysis of ATP possesses poor linearity, the signal is quickly attenuated, and the accuracy

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门