跳转至内容
Merck
CN

167746

Sigma-Aldrich

3-硝基苯甲腈

98%

登录查看公司和协议定价

线性分子式:
O2NC6H4CN
CAS号:
分子量:
148.12
Beilstein:
637674
EC 号:
MDL编号:
UNSPSC代码:
12352100
PubChem化学物质编号:
NACRES:
NA.22

质量水平

检测方案

98%

形式

solid

mp

114-117 °C (lit.)

SMILES字符串

[O-][N+](=O)c1cccc(c1)C#N

InChI

1S/C7H4N2O2/c8-5-6-2-1-3-7(4-6)9(10)11/h1-4H

InChI key

RUSAWEHOGCWOPG-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

应用

3-硝基苯甲腈作为基质,用于基质辅助电离真空质谱法

象形图

Exclamation mark

警示用语:

Warning

危险声明

危险分类

Acute Tox. 4 Oral

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

dust mask type N95 (US), Eyeshields, Gloves

法规信息

新产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Bijay Banstola et al.
The Analyst, 142(10), 1672-1675 (2017-04-27)
We have developed a new ionization approach for matrix-assisted ionization with high temporal resolution using an electrically actuated pulsed valve. Matrix and analyte samples are deposited on a thin metal foil and placed at the inlet of an ambient ionization
Ellen D Inutan et al.
Molecular & cellular proteomics : MCP, 12(3), 792-796 (2012-12-18)
The introduction of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) for the mass spectrometric analysis of peptides and proteins had a dramatic impact on biological science. We now report that a wide variety of compounds, including peptides, proteins, and
Robert B Cody
Journal of the American Society for Mass Spectrometry, 29(8), 1594-1600 (2018-05-31)
Matrix-assisted ionization in vacuum (MAIV) was used to analyze the polyphenol content of ten different tea infusions. Nine different Camellia sinensis infusions were analyzed including three green teas, two black teas, two oolong teas, jasmine tea, and white tea. An
Sarah Trimpin et al.
Analytical chemistry, 85(4), 2005-2009 (2013-02-05)
Matrix assisted ionization vacuum (MAIV) is a new ionization method that does not require high voltages, a laser beam, or applied heat and depends only the proper matrix, 3-nitrobenzonitrile (3-NBN), and the vacuum of the mass spectrometer to initiate ionization.
Yusuf Sert et al.
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 107, 248-255 (2013-02-26)
In the present study, the experimental and theoretical harmonic and anharmonic vibrational frequencies of 4-chloro-3-nitrobenzonitrile were investigated. The experimental FT-IR (400-4000 cm(-1)) and μ-Raman spectra (100-4000 cm(-1)) of the molecule in the solid phase were recorded. Theoretical vibrational frequencies and

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门