Skip to Content

Dear Customer:

The current international situation is complex and volatile, and uncertain tariff policies may potentially impact our product prices. Given these uncertainties, we value your understanding regarding order-related matters.

If you decide to place an order during this period, we reserve the right to adjust the price based on the evolving situation. We understand that market changes may cause inconvenience. We will negotiate with you if there’s a significant price fluctuation due to tariff policy changes before the order’s actual delivery, and in such cases we may adjust or cancel the order as necessary.

Merck
CN
HomeFlow CytometryFlow Cytometry Guide

Flow Cytometry Guide

Flow cytometry is a laboratory technique that is used to analyze cells. Reviewing the basics of flow cytometry, immunodetection methods, key flow cytometry protocol steps, and proper controls helps to ensure accurate flow cytometric analysis. Read on to uncover tips that will make your next flow cytometry experiment successful.

What Is Flow Cytometry?

Flow cytometry is a powerful technique for characterizing and/or sorting heterogeneous suspended cell populations based on their physical and fluorescence characteristics. It can be considered a form of single-cell analysis as flow cytometry is well suited for experiments where quantitative information is desired at a single-cell level for large amounts of cells simultaneously. This can provide information on the number of cells of a given type and the amount of a specific protein in the cell.

Some benefits of flow cytometry include quick analysis, calling attention to differences in cell subpopulations when looking at heterogeneous cell populations, and analyzing subpopulations of heterogeneous cell populations. Flow cytometry is commonly used in immunophenotyping and immuno-oncology research applications to analyze hematological differences in blood, bone marrow, and other sample types.

How It Works

The flow cytometry process works by relying on hydrodynamic focusing of a cell suspension sample to create a single-cell stream, which passes in front of a laser. How the cell scatters incident light is used to determine the size and intracellular complexity of cells at a rate of thousands of particles per second. The analog data generated is then converted to digital data that can be quantified and plotted.

From flow cytometric measurements, specific populations of cells and subsets within these cells can be defined and physically isolated via cell sorting, where cell charge is manipulated based on fluorescence characteristics to allow electrostatic deflection of particles. More precise identification of subpopulations requires the use of probes. Adherent cells and solid tissues may also be analyzed by this technique if they can be successfully dissociated to create a single-cell suspension.

Diagram of typical flow cytometric analysis with laser excitation and detectors.

Figure 1.Diagram of typical flow cytometric analysis.

Components of a Traditional Flow Cytometer

For flow cytometric analysis, at a minimum, even basic, single-laser flow cytometers are typically equipped with sufficient filters to permit the detection of four fluorophores simultaneously. And, it is currently possible to differentiate as many as 18 wavelengths of light in a single experiment. The components of a traditional flow cytometer include:

Fluidics for Sample Processing and Cell Sorting

  • Flow Chamber: Cells in the sample are hydrodynamically focused and presented to the laser.

Optics for Fluorescence Detection

  • Light moves through a system of mirrors and filters.
  • Cells can be measured based on their size, internal complexity, and signal intensity.

Electronics for Signal Processing, Computer Display, and Analysis

  • Photomultiplier tube converts light into electrical signals.
  • Signal is amplified and digitized.

Immunodetection by Flow Cytometry

As with other immunodetection applications, there are several approaches to the use of antibodies to probe for specific cell moieties by flow cytometry. Two main methods are commonly employed: direct detection and indirect detection.

Direct Detection

Direct detection refers to a single-step staining process, which employs a primary antibody that specifically binds to an epitope of interest and that is directly conjugated to a molecule that permits visualization or other detection of the binding event. When probing for antigens localized to the cell surface, fixation of cells is not recommended, as this process renders antigens of interest inaccessible to antibody probes. Hence, it is important to keep unfixed cells viable until the data acquisition is complete. To find antibodies for direct detection, search our Antibody Explorer tool by setting the Search Within to “Primary Antibodies Only” and selecting the application “flow cytometry".

Indirect Detection

In the indirect detection method, incubation with a purified antibody to permit binding to an antigen of interest is followed by a fluorophore-conjugated secondary antibody specific for the primary antibody host isotype, forming a primary-fluorescent secondary antibody scaffold. Increased modularity in an antibody library may be achieved by the use of purified primary antibodies and fluorophore-conjugated secondary antibodies in a variety of wavelengths (or colors) and specific for host isotypes in which the primaries are raised. To find antibodies for indirect detection, search the product table on our Secondary Antibodies page and filter the technique to “flow cytometry”.

Learn more about the detection of fluorochromes in flow cytometry with our guides on selecting the right fluorochrome for your flow cytometry experiment and building the optimal panel for multicolor analysis.

Differences in direct detection vs indirect detection methods in flow cytometry.

Figure 2.Direct detection vs indirect detection methods for flow cytometry.

Key Flow Cytometry Protocol Steps

The four main steps in flow cytometry protocols are:  

  • Sample Preparation: Single-cell suspensions should be prepped through the use of mechanical dissociation methods and detachment techniques such as using enzymatic solutions or calcium chelation reagents.
  • Blocking: Anti-Fc antibody dilution is usually applied to suspended cells to prevent nonspecific binding of primary antibody.
  • Antibody Incubation: Flow cytometry incubation can involve various components such as primary antibodies, secondary antibodies, streptavidin, and fluorochromes.
  • Data Acquisition: Most flow cytometers are accompanied by the necessary software to obtain and transform the signals from cell characteristics. The user then sets the specific software parameters for their experiment.

Discover more details on these steps in our Key Steps in Flow Cytometry Protocol article, or explore troubleshooting tips in our
Flow Cytometry Troubleshooting Guide.

Proper Controls

In addition to cells of interest, every flow cytometry experiment should include the following controls:

  • At least one unstained sample that has been incubated with buffer at each step at the same time as the test samples to optimize flow rates and voltages in the experiment.
  • An appropriate negative control sample, which will be identical to the test samples except for the substitution of the primary antibody with an isotype control that is raised in the same host species as the primary antibody. This controls for nonspecific binding of the secondary antibody. To find isotype controls, browse the table on our Flow Cytometry Antibodies page. You can search the table by keyword, such as “control”.
  • Where possible, a positive control that is comprised of cells known to express each antigen of interest, co-incubated with the test samples, and tested with only a single color.
Related Products
Product No.Product NameDescriptionPricing
FCABS400FMilli-Mark® 抗-FcεRI抗体,γ 亚基-FITCMilli-Mark®, from rabbit
MAB1217FAnti-FMC-7 B-Cell Lymphocyte Marker Antibody, clone FMC-7, FITC conjugatedclone FMC-7, Chemicon®, from mouse
16-202A抗磷酸组蛋白H2A.X(Ser139)抗体,克隆JBW301,FITC结合物clone JBW301, Upstate®, from mouse
FCMAB317PEMilli-Mark® 抗-NeuN-PE抗体,克隆A60clone A60, Milli-Mark®, from mouse
16-256抗磷脂酰丝氨酸抗体,克隆1H6,Alexa Fluor 488clone 1H6, Upstate®, from mouse
FCMAB108A4Anti-phospho-SMC1 (Ser957) Antibody, clone 5D11G5 Alexa Fluor 488clone 5D11G5, from mouse, ALEXA FLUOR 488
E4011ExtrAvidin®−R-藻红蛋白buffered aqueous solution
P4247Anti-Potassium Channel Kv1.3 (extracellular)−FITC antibody produced in rabbitaffinity isolated antibody, lyophilized powder
F5662抗HLA I类抗原单克隆抗体clone W6/32, purified immunoglobulin, buffered aqueous solution
MAB1285FX抗HLA-B27抗体,克隆HLA.ABC.m3,FITC偶联clone HLA-ABC-m3, Chemicon®, from mouse
FCMAB312FMilli-Mark® Anti-Galactocerebroside-FITC Antibody, clone mGalCclone mGalC, Milli-Mark®, from mouse
FCMAB412FMilli-Mark® 抗胶原Ⅰ型-FITC抗体,克隆5D8-G9clone 5D8-G9, Milli-Mark®, from mouse
16-232抗-α-微管蛋白抗体,克隆DM1A,Alexa Fluor 488结合物clone DM1A, Upstate®, from mouse
SAB4700448单克隆抗 MYC-FITC,(C 端) 小鼠抗clone 9E10, purified immunoglobulin, buffered aqueous solution
MAB1794H抗人B细胞(CD19)抗体(克隆FMC63,藻红蛋白偶联)clone FMC63, Chemicon®, from mouse
FCMAB176FMilli-Mark Anti-CD8 -FITC Antibody, clone DK25clone DK25, Milli-Mark®, from mouse
MAB377抗NeuN抗体,克隆A60clone A60, Chemicon®, from mouse
MABE343抗嘌呤霉素抗体,克隆 12D10clone 12D10, from mouse
05-201抗-Fas抗体(人,激活),克隆CH11clone CH11, Upstate®, from mouse
MAB1398Z抗-PECAM-1抗体,克隆2H8,无叠氮化物clone 2H8, Chemicon®, from hamster(Armenian)
Sign In To Continue

To continue reading please sign in or create an account.

Don't Have An Account?