跳转至内容
Merck
CN
HomeMammalian Cell CultureCoating Tissue Culture Plates with Vitronectin

Coating Tissue Culture Plates with Vitronectin

Vitronectin (Product No. SRP3186) is used to coat culture vessels for cells attachment. Below is a suggested coating protocol for a 96-well plate at a coating concentration of 0.5 µg/cm2. Note that the optimal concentration will vary with each cell line. For culture vessels other than a 96-well plate, scale this protocol accordingly. To calculate the working concentration of vitronectin, use Table 1, or the following equation:

Working concentration calculation

Working concentration calculation Example:

To coat a 96-well plate (surface area is 0.3 cm2/well) at a coating concentration of 0.5 µg/cm2, prepare 9.6-10 mL of diluted vitronectin solution (0.1 mL/well × 96 wells, Table 1) at the following concentration:

Working concentration calculation2

The vitronectin working concentration in this example is 1.5 µg/mL. Adding 0.1 mL per well of this working solution will yield a coating concentration of 0.5 µg/cm2.

Bioassay
Purity

Bioassay
The biological activity of human, recombinant Vitronectin (VTN) expressed in HEK 293 cells (SRP3186) was measured in a cell attachment assay using CHO cells. The EC50 is defined as the effective concentration that elicits a 50% increase in cell attachment in a cell-based bioassay.

Purity
The purity of human, recombinant vitronectin expressed in HEK 293 cells (SRP3186) was assessed on SDS-PAGE (1.25 μg/lane.) followed by InstantBlue™ stain (ISB1L). (Representative result)

Materials

  • 1X PBS
  • Pure water (e.g.,Product No. W3500)
  • Sterile tissue culture 96-well plate with a lid (Product No. CLS3300)
  • Recombinant human vitronectin (Product No. SRP3186)

Protocol

A. Preparation of vitronectin

  1. Reconstitute the lyophilized vitronectin with sterile water, to a final concentration of 100-300 µg/mL. This stock solution can be stored at 2-8 oC for up to one week. For extended storage, it is best to further dilute in a buffer containing a carrier protein (example 0.1% BSA) and store in working aliquots at -20 to -80 oC.
  2. Further dilute the reconstituted vitronectin stock solution in 1X PBS to a final concentration of 1.5 µg/mL. For example, for a 10 mL solution (sufficient to coat one 96-well plate), dilute 75 µL of 200 µg/mL stock solution in 10 mL of 1X PBS.

B. Coating the plate

  1. To each well, add 100 µL of the 1.5 µg/mL vitronectin solution, for a final coating concentration of 0.5 µg/cm2.
  2. Cover the plate with a lid. For best results it is best to incubate the plate for 2 hours at 37 oC in 5% CO2 and 95% air, and then over-night at 2-8 oC.
  3. Aspirate the vitronectin solution, being careful not to scratch the coated vitronectin. The plate is now ready to use.
  4. Wash each well 3 times with 1XPBS.
  5. For immediate use, aspirate the 1XPBS. Alternatively, the coated plate can be stored for up to one week at 2-8 oC with 1XPBS, covered and wrapped in laboratory film.
  6. Before use, pre-warm the coated plate.
Table 1Volumes and working concentrations of vitronectin for various tissue culture vessels
Materials
Loading
登录以继续。

如要继续阅读,请登录或创建帐户。

暂无帐户?