跳转至内容

尊敬的客户:

目前国际形势复杂多变,关税政策尚不明朗,这可能对我们的产品价格产生一定影响。在此情况下,我们希望就订单事宜与您进行友好沟通。

基于当前的不确定性,如果您选择在此期间下单,我们将保留根据实际情况调整价格的权利。同时,我们也理解市场变化可能给您带来的困扰,因此如果在订单实际发货前因关税政策变动导致价格出现较大波动,默克将与您进行协商讨论并视情况对订单进行调整或取消。

We are planning system maintenance between Friday, Apr 18 at 9:00 PM CDT and Saturday, Apr 19 at 9:00 AM CDT. This will impact both web and offline transactions, including online orders, quotes, price and availability checks, and order status inquiries. We apologize for any inconvenience.

关于应对近期政策变化的重要更新,请点击此处查看详情。

Merck
CN
  • Automated online dual-column extraction coupled with teicoplanin stationary phase for simultaneous determination of (R)- and (S)-propranolol in rat plasma using liquid chromatography-tandem mass spectrometry.

Automated online dual-column extraction coupled with teicoplanin stationary phase for simultaneous determination of (R)- and (S)-propranolol in rat plasma using liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2003-04-23)
Yuan-Qing Xia, Ray Bakhtiar, Ronald B Franklin
摘要

An automated online sample extraction method for rat plasma was developed and validated for the quantification of (R)- and (S)-propranolol following the intravenous administration of either the racemate or the individual enantiomers at 5 mg/kg. A dual-column extraction system coupled to a chiral stationary phase (CSP) was used in conjunction with liquid chromatography-tandem mass spectrometry. In this method, two Oasis HLB extraction columns (50x1.0 mm) in parallel were used for online plasma sample purification and teicoplanin CSP (Chirobiotic T) was used for the enantiomeric separation. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for re-conditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a relatively shorter run time and higher throughput. The lower limit of detection was 0.5 ng/ml and the lower limit of quantification was 2 ng/ml for each enantiomer using 25 microl of rat plasma. The method was validated with a linear calibration curve between 2 and 2000 ng/ml for (R)- and (S)-propranolol, respectively. The intra- and inter-day precision (C.V.) was no more than 7.6% and the accuracy of the assay was between 92 and 103%. The teicoplanin CSP proved to be rugged with excellent reproducibility of chromatographic parameters.

材料
货号
品牌
产品描述

Supelco
Astec® CHIROBIOTIC® T 手性 HPLC 色谱柱, 5 μm particle size, L × I.D. 25 cm × 4.6 mm
登录查看公司和协议定价
货号包装规格是否有货价格数量
100 mg
国内现货,预计发货时间 April 21, 2025
详情...
CN¥726.62
Supelco
Astec® CHIROBIOTIC® T 手性 HPLC 色谱柱, 5 μm particle size, L × I.D. 15 cm × 4.6 mm
登录查看公司和协议定价
货号包装规格是否有货价格数量
100 mg
国内现货,预计发货时间 April 21, 2025
详情...
CN¥726.62
Supelco
Astec® CHIROBIOTIC® T 手性 HPLC 色谱柱, 5 μm particle size, L × I.D. 5 cm × 4.6 mm
登录查看公司和协议定价
货号包装规格是否有货价格数量
100 mg
国内现货,预计发货时间 April 21, 2025
详情...
CN¥726.62
Supelco
Astec® CHIROBIOTIC® T 手性 HPLC 色谱柱, 5 μm particle size, L × I.D. 15 cm × 2.1 mm
登录查看公司和协议定价
货号包装规格是否有货价格数量
100 mg
国内现货,预计发货时间 April 21, 2025
详情...
CN¥726.62
Supelco
Astec® CHIROBIOTIC® T 手性 HPLC 色谱柱, 5 μm particle size, L × I.D. 25 cm × 10 mm
登录查看公司和协议定价
货号包装规格是否有货价格数量
100 mg
国内现货,预计发货时间 April 21, 2025
详情...
CN¥726.62
Supelco
Astec® CHIROBIOTIC® T 手性 HPLC 色谱柱, 5 μm particle size, L × I.D. 25 cm × 2.1 mm
登录查看公司和协议定价
货号包装规格是否有货价格数量
100 mg
国内现货,预计发货时间 April 21, 2025
详情...
CN¥726.62
Supelco
Astec® CHIROBIOTIC® T 手性 HPLC 色谱柱, 5 μm particle size, L × I.D. 10 cm × 2.1 mm
登录查看公司和协议定价
货号包装规格是否有货价格数量
100 mg
国内现货,预计发货时间 April 21, 2025
详情...
CN¥726.62
Supelco
Astec® CHIROBIOTIC® T 手性 HPLC 色谱柱, 5 μm particle size, L × I.D. 10 cm × 4.6 mm
登录查看公司和协议定价
货号包装规格是否有货价格数量
100 mg
国内现货,预计发货时间 April 21, 2025
详情...
CN¥726.62