跳转至内容
Merck
CN

Low skin temperatures produced by new skin refrigerants.

The Journal of dermatologic surgery and oncology (1985-12-01)
R A Strick, R L Moy
摘要

Temperatures produced by Cryosthesia -30 degrees C, Cryosthesia -60 degrees C, and Frigiderm were measured in minipigs. Cryosthesia -60 degrees C and Cryosthesia -30 degrees C were both found to rapidly lower skin temperatures to levels that have been shown to cause cell injury, necrosis, and loss of melanocytes. Use of these agents requires extreme caution in dermabrasion.