跳转至内容

尊敬的客户:

目前国际形势复杂多变,关税政策尚不明朗,这可能对我们的产品价格产生一定影响。在此情况下,我们希望就订单事宜与您进行友好沟通。

基于当前的不确定性,如果您选择在此期间下单,我们将保留根据实际情况调整价格的权利。同时,我们也理解市场变化可能给您带来的困扰,因此如果在订单实际发货前因关税政策变动导致价格出现较大波动,默克将与您进行协商讨论并视情况对订单进行调整或取消。

We are planning system maintenance between Friday, Apr 18 at 9:00 PM CDT and Saturday, Apr 19 at 9:00 AM CDT. This will impact both web and offline transactions, including online orders, quotes, price and availability checks, and order status inquiries. We apologize for any inconvenience.

关于应对近期政策变化的重要更新,请点击此处查看详情。

Merck
CN
  • Combination of dispersive solid phase extraction with solidification organic drop-dispersive liquid-liquid microextraction based on deep eutectic solvent for extraction of organophosphorous pesticides from edible oil samples.

Combination of dispersive solid phase extraction with solidification organic drop-dispersive liquid-liquid microextraction based on deep eutectic solvent for extraction of organophosphorous pesticides from edible oil samples.

Journal of chromatography. A (2020-08-22)
Elham Zahiri, Jalil Khandaghi, Mir Ali Farajzadeh, Mohammad Reza Afshar Mogaddam
摘要

A dispersive solid phase extraction method was combined with deep eutectic solvent-based solidification of floating organic drop-dispersive liquid-liquid microextraction and used for the extraction/preconcentration of some organophosphorus pesticides residues from edible oil samples. The extracted analytes were quantified with gas chromatography-nitrogen phosphorous detector. In this procedure, the sample lipids are saponified with a sodium hydroxide solution and then the analytes are adsorbed onto a primary secondary amine sorbent. After that the analytes are desorbed with acetone as an elution/dispersive solvent and mixed with choline chloride: 3,3-dimethyl butyric acid deep eutectic solvent and the mixture is rapidly dispersed into deionized water. Then, the obtained cloudy solution is centrifuged and placed into an ice bath. The extraction solvent is solidified on the top of the solution. Finally, it is removed and dissolved in acetonitrile, and 1 µL of the solution is injected into the separation system. Validation of the method showed that limits of detection and quantification were in the ranges of 0.06-0.24 and 0.20-0.56 ng mL-1, respectively. Enrichment factors and extraction recoveries of the analytes ranged from 170-192 and 68-77%, respectively. The method had an acceptable precision with relative standard deviations less than ≤9.2% for intra- (n=6) and inter-day (n=6) precisions at four concentrations (3, 10, 50, and 250 ng mL-1, each analyte). Finally the method was used for determination of the analytes in five edible oil samples.

材料
货号
品牌
产品描述

Sigma-Aldrich
3,3-二甲基丁酸, 98%
登录查看公司和协议定价
货号包装规格是否有货价格数量
3 ea
预计发货时间 2025年4月21日
详情...
¥4,780.13