Skip to Content

The system is currently under maintenance, and the website's ordering function is temporarily unavailable. We sincerely regret any inconvenience this may cause. If you need any further assistance, please contact our Customer Contact Center at 400 620 3333.

For important updates on recent policy changes, please click here for more details.

Merck
CN
HomeQuEChERS Sample Preparation MethodNeonicotinoids Ban: Impact on Plant Material

Neonicotinoids Ban: Impact on Plant Material

QuEChERs Sample cleanup and LC-MS method using a Fused-Core® particle column complemented by a comprehensive line of reference materials

Banned and other neonicotinoids from plant material

On Friday, April 27, 2018, representatives of the Member States of the European Union decided to  ban the use of three products from the neonicotinoid family of insecticides as they have been deemed dangerous to bees when used on all outdoor crops. Proposed by the European Commission, the  text concerns three neonicotinoids (clothianidin, imidacloprid, and thiamethoxam), whose use it had already partially restricted since December 2013. This time, the moratorium was not only expanded, but it was also generalized to include all field crops, leaving only greenhouse use permitted.

The application below demonstrates the extraction and clean up of these banned compounds and others of the neonicotinoid class from dandelion blossoms using the QuEChERS methodology.

For the QuEChERS approach, Supel™ QuE tubes were used for extraction (Acetate) and clean up (PSA/C18) prior to analysis of seven neonicotinoid pesticides. For the LC-MS analysis (Figure 1), an Ascentis® Express C18 Fused-Core® particle column was chosen to achieve high efficiency at relatively low back pressure compared to sub-2 micron UHPLC columns.

Separation of Neonicotinoids on Ascentis® Express C18

Figure 1.Separation of Neonicotinoids on Ascentis® Express C18

Conditions
Sample/matrix3 g ground dandelion blossoms, homogenized in 10 mL water, spiked at 50ng/g
Extraction processadd 25 mL of acetonitrile; add contents of Supel™ QuE acetate extraction tube (55234-U); shake immediately for 1 min; centrifuge at 3400 rpm for 5 min
Cleanup processTransfer 1 mL of the acetonitrile layer to Supel™ QuE PSA/C18 cleanup tube (55288-U); shake 1 min.; centrifuge at 3500 rpm for 3 min.; (draw off 700 µL of supernatant, evaporate to dryness at 50 °C under nitrogen; reconstitute in 200 µL of 50:50 0.1% formic acid:0.1% formic acid in methanol)
ColumnAscentis® Express C18, 10 cm x 3.0 mm I.D., 2.7 µm particles (53814-U)
Column temperature25 °C
Mobile phase[A] 0.1% formic acid in water; [B] 0.1% formic acid in methanol
Gradient30% B from 0 to 5 min; to 100% B in 0.2 min; held at 100% B for 5.3 min; to 30% B in 0.5 min; held at 30% B for 5 min
Flow rate500 µL/min
Pressure3800 psi (262 bar)
Injection3 µL
DetectorMS, ESI(+), MRM, m/z 203.2/129.2, 271.2/225.0, 292.1/211.0, 256.0/175.2, 250.0/132.0, 223.2/126.0, 253.0/125.8
Product NumberProduct NameProduct DescriptionPricing
39246Acetamiprid-d3PESTANAL®, analytical standard
32979Acetamiprid-N-desmethylPESTANAL®, analytical standard
1.00029Acetonitrilehypergrade for LC-MS LiChrosolv®
53814-UAscentis® Express C18, 2.7 μm HPLC Column2.7 μm particle size, L × I.D. 10 cm × 3 mm
686786-Chloropyridine-3-carboxylic acidPESTANAL®, analytical standard
33674N-(6-Chloro-3-pyridylmethyl)-N-cyano-N-methylacetamidinePESTANAL®, analytical standard
33589ClothianidinPESTANAL®, analytical standard
56816Clothianidin-d3PESTANAL®, analytical standard
73348N-DesmethylthiamethoxamPESTANAL®, analytical standard
37052Desnitro-imidacloprid hydrochloridePESTANAL®, analytical standard
32499DinotefuranPESTANAL®, analytical standard
5.33002Formic acid 98% - 100%for LC-MS LiChropur
193866-Hydroxypyridine-3-carboxylic acidPESTANAL®, analytical standard
37894ImidaclopridPESTANAL®, analytical standard
68694Imidaclopridcertified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
46341Imidacloprid solution100 μg/mL in acetonitrile, PESTANAL®, analytical standard
34170Imidacloprid-d4PESTANAL®, analytical standard
34534Imidacloprid-olefinPESTANAL®, analytical standard
315342-ImidazolidonePESTANAL®, analytical standard
1.06035Methanolhypergrade for LC-MS LiChrosolv®
Sign In To Continue

To continue reading please sign in or create an account.

Don't Have An Account?