Skip to Content
Merck
CN

Measurement of plasma protein and lipoprotein binding of pyrethroids.

Journal of pharmacological and toxicological methods (2014-06-15)
Pankaj K Sethi, S Muralidhara, James V Bruckner, Catherine A White
ABSTRACT

A simple, reliable procedure was developed to measure binding of pyrethroid insecticides to total proteins and lipoproteins of rat and human plasma. The extent of binding of (14)C-labeled deltamethrin (DLM), cis-permethrin (CIS) and trans-permethrin (TRANS) was quantified by a 3-step organic solvent extraction technique. Rat and human plasma samples, containing NaF to inhibit esterases, were spiked with a range of concentrations of each radiolabeled pyrethroid. Protein binding reached equilibrium within ~1h of incubation at 37°C. The samples were extracted in turn with: isooctane to collect the unbound fraction; 2-octanol to extract the lipoprotein-bound fraction; and acetonitrile to obtain the protein-bound fraction. Absolute recoveries of DLM, CIS and TRANS ranged from 86 to 95%. Adherence of these very lipophilic chemicals to glass and plastic was minimized by using silanized glass vials and LoBind® plastic pipettes. The method's ability to distinguish lipoprotein from protein binding was confirmed by experiments with diazepam and cyclosporine, drugs that bind selectively to albumin and lipoproteins, respectively. This procedure was effectively utilized for studies of the species-dependence of plasma protein and lipoprotein binding of three pyrethroids for inclusion in physiologically-based pharmacokinetic models of pyrethroids for use in health risk assessments of the insecticides in children and adults.

MATERIALS
Product Number
Brand
Product Description

Supelco
Density Standard 692 kg/m3, H&D Fitzgerald Ltd. Quality
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2-Octanol, ≥97%, FG
Sigma-Aldrich
2-Octanol, 97%
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Supelco
Hexamethyldisilazane, for GC derivatization, LiChropur, ≥99.0% (GC)
Sigma-Aldrich
2,2,4-Trimethylpentane, anhydrous, 99.8%
Sigma-Aldrich
(±)-2-Octanol, ReagentPlus®, ≥99.5% (GC)
Supelco
2,2,4-Trimethylpentane, analytical standard
Supelco
Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
2,2,4-Trimethylpentane, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.5%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Sodium fluoride, BioReagent, suitable for insect cell culture, ≥99%
Sigma-Aldrich
Hexamethyldisilazane, reagent grade, ≥99%
Sigma-Aldrich
Sodium fluoride, 99.99% trace metals basis
Sigma-Aldrich
Hexamethyldisilazane, ReagentPlus®, 99.9%
Sigma-Aldrich
Sodium fluoride, BioXtra, ≥99%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Supelco
Sodium Fluoride, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
(±)-2-Octanol, analytical standard
Sigma-Aldrich
Sodium fluoride 0.5 M solution
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Hexamethyldisilazane, produced by Wacker Chemie AG, Burghausen, Germany, ≥97.0% (GC)
Sigma-Aldrich
(±)-2-Octanol, ≥96.0% (GC)
Sigma-Aldrich
Sodium fluoride, anhydrous, powder, 99.99% trace metals basis
Supelco
Fluoride ion solution for ISE, 0.1 M F-, analytical standard (for ion-selective electrodes)
Sigma-Aldrich
Sodium fluoride, ACS reagent, ≥99%