Skip to Content

尊敬的客户:

目前国际形势复杂多变,关税政策尚不明朗,这可能对我们的产品价格产生一定影响。在此情况下,我们希望就订单事宜与您进行友好沟通。

基于当前的不确定性,如果您选择在此期间下单,我们将保留根据实际情况调整价格的权利。同时,我们也理解市场变化可能给您带来的困扰,因此如果在订单实际发货前因关税政策变动导致价格出现较大波动,默克将与您进行协商讨论并视情况对订单进行调整或取消。

关于应对近期政策变化的重要更新,请点击此处查看详情。

Merck
CN
All Photos(1)

Key Documents

G005817

LC/MS (TOF) Analysis of Antiarrhythmic Drugs and Metabolites on Ascentis® Express HILIC

application for HPLC

Sign Into View Organizational & Contract Pricing

Select a Size

500 G
CN¥256.13
6 X 500 G
CN¥870.52

CN¥256.13


Please contact Customer Service for Availability


Select a Size

Change View
500 G
CN¥256.13
6 X 500 G
CN¥870.52

About This Item


CN¥256.13


Please contact Customer Service for Availability

technique(s)

HPLC: suitable

test parameters

column: Ascentis Express HILIC, 10 cm x 2.1 mm I.D., 2.7 μm particles (53939-U)
mobile phase: [A] 5 mM ammonium formate; [B] 5 mM ammonium formate in acetonitrile; (5:95, A:B, pH 7.0 with formic acid)
flow rate: 0.4 mL/min
column temp.: 35 °C
detector: ESI(+), full scan, m/z 200-800
injection: 0.5 μL
sample: each compound, 300 ng/mL in 1% formic acid acetonitrile:water, 75:25

suitability

application for HPLC

application(s)

clinical

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
31307223506208290
assay

99%

assay

≥99%

assay

≥99%, 99.0-105.0% (ACS specification)

assay

≥99% (by assay)

grade

reagent grade

grade

ACS reagent, puriss. p.a.

grade

ACS reagent

grade

ACS reagent

mp

176 °C (dec.) (lit.)

mp

176 °C (dec.) (lit.)

mp

176 °C (dec.) (lit.)

mp

176 °C (dec.) (lit.)

vapor pressure

0.01 mmHg ( 20 °C)

vapor pressure

0.01 hPa ( 20 °C)

vapor pressure

0.01 mmHg ( 20 °C)

vapor pressure

-

pH

5-8 (25 °C, 147 g/L)

pH

4.5-8.0 (25 °C, 5%)

pH

4.5-8.5 (25 °C, 5%)

pH

-

Analysis Note

The basic nature of these compounds makes them targets for HILIC chromatographic separation. HILIC mobile phases consist of a high composition of acetonitrile, which facilitates the direct analysis of precipitated plasma samples without the need for additional sample solvent exchange. In most cases, the high organic mobile phase also facilitates increased analyte response with ESI(+) MS detection. Separation was performed on an Ascentis Express HILIC Fused-Core HPLC column. High purity solvents provided clean, robust operation. Cerilliant CRMs provided reliable quantification.

Legal Information

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

Analyte

Description

    Amiodarone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
    N-Desethylamiodarone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
    Lidocaine solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
    (±)-Flecainide solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service