Skip to Content
Merck
CN

LC/MS Analysis of Amino Acids on Ascentis® Express HILIC

LC/MS Analysis of Amino Acids on Ascentis® Express HILIC application for HPLC

Materials

analytical column

Product No.
Description
Pricing

Ascentis® Express HILIC, 2.7 μm HPLC Column

2.7 μm particle size, L × I.D. 15 cm × 4.6 mm

standard

Product No.
Description
Pricing

Tryptophan

Pharmaceutical Secondary Standard; Certified Reference Material

Methionine

European Pharmacopoeia (EP) Reference Standard

Tyramine

analytical standard

Tryptamine

analytical standard

Alanine

European Pharmacopoeia (EP) Reference Standard

β-Alanine

analytical standard

CONDITIONS

column

Ascentis Express HILIC, 15 cm x 4.6 mm I.D., 2.7 μm particles (53981-U)

mobile phase

[A] 13 mM ammonium acetate in 10:90 (v/v) water: acetonitrile; [B] 13 mM ammonium acetate in water

gradient

held at 0% B for 1 min; 0 to 90% B in 19 min

flow rate

1.0 mL/min

column temp.

35 °C

detector

ESI(+)

injection

10 μL

sample

10 mg/L in Mobile Phase A

Description

Legal Information