Safety Information

1.09351

Supelco

Potassium hydroxide solution

c(KOH) = 0.5 mol/l (0.5 N) in methanol, ready-to-use volumetric solution for titration in non-aqueous media, Titripur®

Synonym(s):

KOH Methanol Solution

Sign Into View Organizational & Contract Pricing

Select a Size

1 L
¥741.18
1 L
¥788.11

¥741.18


Estimated to ship on2025年6月03日Details


Request more information

Select a Size

Change View
1 L
¥741.18
1 L
¥788.11

About This Item

UNSPSC Code:
12352305
NACRES:
NA.21

¥741.18


Estimated to ship on2025年6月03日Details


Request more information

Product Name

Potassium hydroxide solution in methanol, c(KOH) = 0.5 mol/l (0.5 N), Titripur®

Quality Level

product line

Titripur®

form

liquid

autoignition temp.

455 °C (Methanol)

quality

Analyzed in our ISO 17025 accredited QC lab

expl. lim.

5.5-44 % (v/v) Methanol()

reaction suitability

reaction type: Acid-base reactions

concentration

0.5 M

technique(s)

titration: suitable

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
111587111787109114
reaction suitability

reaction type: Acid-base reactions

reaction suitability

reaction type: Acid-base reactions

reaction suitability

reaction type: Acid-base reactions

reaction suitability

reaction type: Acid-base reactions

technique(s)

titration: suitable

technique(s)

titration: suitable

technique(s)

titration: suitable

technique(s)

titration: suitable

product line

Titripur®

product line

Titripur®

product line

Titripur®

product line

Titripur®

form

liquid

form

liquid

form

liquid

form

liquid

autoignition temp.

455 °C (Methanol)

autoignition temp.

455 °C (Methanol)

autoignition temp.

455 °C (Methanol)

autoignition temp.

425 °C (ethanol)

quality

Analyzed in our ISO 17025 accredited QC lab

quality

Analyzed in our ISO 17025 accredited QC lab

quality

Analyzed in our ISO 17025 accredited QC lab

quality

Analyzed in our ISO 17025 accredited QC lab

Features and Benefits

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Packaging

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Analysis Note

Form liquid
Amount-of-substance concentration 0.4975 - 0.5025 mol/L
Measurement uncertainty ± 0.0015 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Legal Information

Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Product No.
Description
Pricing

Signal Word

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Eye Dam. 1 - Flam. Liq. 2 - Met. Corr. 1 - Skin Corr. 1B - STOT SE 1

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point(F)

44.6 °F

Flash Point(C)

7 °C

Regulatory Information

危险化学品

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Select a Product Number

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service