跳转至内容
Merck
CN

CGD1

Sigma-Aldrich

细胞生长测定试剂盒,基于MTT法

登录查看公司和协议定价

别名:
Mitochondrial activity assay
UNSPSC代码:
12352207
NACRES:
NA.75

包装

pkg of 1 kit

质量水平

技术

UV/Vis spectroscopy: suitable
protein quantification: suitable

Amax

570 nm

应用

cell analysis
detection

检测方法

colorimetric

运输

dry ice

储存温度

−20°C

一般描述

细胞生长测定试剂盒(基于MTT)设计用于以分光光度法测量细胞生长,作为活细胞中线粒体活性的函数。MTT(3-(4,5 -二甲基噻唑-2)- 2,5 -二苯基溴化四唑)系统是一种简单、准确、可重复性的方法,可通过线粒体脱氢酶活性测量活细胞活性。

应用

细胞生长测定试剂盒(基于MTT)已用于:
  • 测定成骨前细胞的细胞活力
  • 正常人前列腺间质和上皮细胞的MTT(3-(4,5 -二甲基噻唑-2)- 2,5 -二苯溴化四唑)检测
  • 测定原代宫颈上皮细胞的细胞活力

包装

每个试剂盒包括5瓶试剂,每瓶含1 mL 5 mg/ml MTT的RPMI溶液(无酚红)和50 mL MTT溶剂(0.1N盐酸的无水异丙醇溶液)。 优化后的各组分体积大小尤其适合多孔板细胞生长。 MTT溶液按总培养体积的10%添加,因此每个试剂盒的测试次数取决于培养容量和/或体积大小。

相关产品

产品编号
说明
价格

警示用语:

Danger

危险分类

Eye Irrit. 2 - Flam. Liq. 2 - Muta. 2 - STOT SE 3

靶器官

Central nervous system

WGK

WGK 3

闪点(°F)

53.6 °F

闪点(°C)

12 °C

法规信息

新产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

  1. Which document(s) contains shelf-life or expiration date information for a given product?

    If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.

  2. How do I get lot-specific information or a Certificate of Analysis?

    The lot specific COA document can be found by entering the lot number above under the "Documents" section.

  3. Can we use media with phenol red with Product CGD1, Cell Growth Determination Kit?

    You most likely would not be able to use a medium containing phenol red with this kit. We have found that the phenol red can contribute to higher background, and therefore lower sensitivity.

  4. What is the difference between Product No. CGD1, Cell Growth Determination Kit and Product No.TOX1, In Vitro Toxicology Assay Kit?

    Product No. CGD1 and TOX1 are both MTT based assays. The major difference between Product No. CGD1 and TOX1 is that TOX1 contains 10 % Triton X-100 in the solubilization solution for better lysis of the cells and solubilization of the MTT.  If there is complete cell lysis, the results obtained with both kits would be the same.  The MTT in this kit is a solution, whereas the TOX1 assay kit contains the MTT as a powder that is solubilized before use.

  5. What are the components of the Product No. CGD1, Cell Growth Determination Kit and Product No.TOX1, In Vitro Toxicology Assay Kit?

    CGD1 contains 5 vials of 5 mg/vial of MTT and 50 ml of MTT solvent (solubilization solution) and TOX1 contains 5 vials of 15 mg/vial of MTT and 125 ml of solubilization solution.

  6. Is 10% fetal bovine serum (FBS) in the culture medium compatible with Product CGD1, Cell Growth Determination Kit?

    High protein levels may form a precipitate when the MTT solubilization solution is added. Samples with protein concentrations equivalent to 10% FBS or 4 mg/mL protein seem acceptable.

  7. How do I find price and availability?

    There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote.  USA customers:  1-800-325-3010 or view local office numbers.

  8. What is the Department of Transportation shipping information for this product?

    Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product. 

  9. Is the MTT assay quantitative?

    The MTT asay is a method to assess cell viability.  This assay is a semiquantitative assay. The assay is used to compare the viability changes in treated cells to untreated cells. The absorbance is indicative of the cell number. The higher the absorbance, the greater the number of viable cells present. Most researchers compare the absorbance of the two samples as a ratio (ABS treated cells/ABS untreated cells) to get a fold increase/decrease in cell number.   

  10. What is the difference between product CGD1, Cell Growth Determination Kit and product TOX1, In Vitro Toxicology Assay Kit?

    Product CGD1 and TOX1 are both MTT based assays. The major difference between product CGD1 and TOX1 is that TOX1 contains 10 % Triton X-100 in the solubilization solution for better lysis of the cells and solubilization of the MTT.  If there is complete cell lysis, the results obtained with both kits would be the same.  The MTT in this kit is a solution, whereas the TOX1 assay kit contains the MTT as a powder that is solubilized before use.

  11. My question is not addressed here, how can I contact Technical Service for assistance?

    Ask a Scientist here.

Alejandra Castilla et al.
Journal of vascular research, 47(1), 45-53 (2009-08-13)
Angiogenesis is essential for the growth and maturation of the ovarian follicle and its transition into the corpus luteum. In addition to the main proangiogenic factors, vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF), follicular fluid (FF)
Mengxiong Wang et al.
Oncogene, 38(22), 4264-4282 (2019-02-06)
While HER2 and EGFR are overexpressed in breast cancers and multiple other types of tumors, the use of EGFR and/or HER2 inhibitors have failed to cure many cancer patients, largely because cancers acquire resistance to HER2/EGFR-specific drugs. Cancers that overexpress
Qiuyu Lin et al.
Journal of cellular and molecular medicine, 22(10), 4640-4652 (2018-07-25)
This study is aimed to investigate the methylation level of candidate genes and its impact on thyroid carcinoma (THCA) development. Infinium Human Methylation 450 BeadChip Arrays by Illumina (Illumina HM450K) was the most popular CpG microarray platform widely used in
Ahran Pae et al.
The journal of advanced prosthodontics, 6(2), 96-102 (2014-05-21)
This study was performed to characterize the effects of zirconia coated with calcium phosphate and hydroxyapatite compared to smooth zirconia after bone marrow-derived osteoblast culture. Bone marrow-derived osteoblasts were cultured on (1) smooth zirconia, (2) zirconia coated with calcium phosphate
Mariarita Perri et al.
Biochimica et biophysica acta, 1800(9), 993-1001 (2010-07-06)
Vitamin A is suggested to be protective against oxidative stress. However, different authors observed pro-oxidant effects of retinoids both in experimental works and clinical trials. These discordances are the bases for the investigation of the proliferative and anti-proliferative properties of

商品

Quality control guidelines to maintain high quality authenticated and contamination-free cell cultures. Free ECACC handbook download.

用于维持高质量经验证的无污染细胞培养的质量控制指南。免费下载ECACC手册。

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门