Skip to Content
Merck
CN
  • A metabolite profiling approach to identify biomarkers of flavonoid intake in humans.

A metabolite profiling approach to identify biomarkers of flavonoid intake in humans.

The Journal of nutrition (2009-10-09)
Wai Mun Loke, Andrew M Jenner, Julie M Proudfoot, Allan J McKinley, Jonathan M Hodgson, Barry Halliwell, Kevin D Croft
ABSTRACT

Flavonoids are phytochemicals that are widespread in the human diet. Despite limitations in their bioavailability, experimental and epidemiological data suggest health benefits of flavonoid consumption. Valid biomarkers of flavonoid intake may be useful for estimating exposure in a range of settings. However, to date, few useful flavonoid biomarkers have been identified. In this study, we used a metabolite profiling approach to examine the aromatic and phenolic profile of plasma and urine of healthy men after oral consumption of 200 mg of the pure flavonoids, quercetin, (-)-epicatechin, and epigallocatechin gallate, which represent major flavonoid constituents in the diet. Following enzymatic hydrolysis, 71 aromatic compounds were quantified in plasma and urine at 2 and 5 h, respectively, after flavonoid ingestion. Plasma concentrations of different aromatic compounds ranged widely, from 0.01 to 10 micromol/L, with variation among volunteers. None of the aromatic compounds was significantly elevated in plasma 2 h after consumption of either flavonoid compared with water placebo. This indicates that flavonoid-derived aromatic compounds are not responsible for the acute physiological effects reported within 2 h in previous human intervention studies involving flavonoids or flavonoid-rich food consumption. These effects are more likely due to absorption of the intact flavonoid. Our urine analysis suggested that urinary 4-ethylphenol, benzoic acid, and 4-ethylbenzoic acid may be potential biomarkers of quercetin intake and 1,3,5-trimethoxybenzene, 4-O-methylgallic acid, 3-O-methylgallic acid, and gallic acid may be potential markers of epigallocatechin gallate intake. Potential biomarkers of (-)-epicatechin were not identified. These urinary biomarkers may provide an accurate indication of flavonoid exposure.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Vanillic acid, purum, ≥97.0% (HPLC)
Epicatechin, primary reference standard
Sigma-Aldrich
4-Ethylbenzoic acid, 99%
Sigma-Aldrich
Homovanillic acid, Fluorimetric reagent
Sigma-Aldrich
Pyrocatechol, ≥99%
Sigma-Aldrich
Hydrocinnamic acid, 99%
Sigma-Aldrich
Vanillic acid, 97%
Sigma-Aldrich
Pyrocatechol, purified by sublimation, ≥99.5%
Sigma-Aldrich
2-Hydroxyphenylacetic acid, ReagentPlus®, 99%
Sigma-Aldrich
3,4-Dihydroxyphenylacetic acid, 98%
Sigma-Aldrich
4-Hydroxyphenylacetic acid, 98%
Supelco
(−)-Epicatechin, analytical standard
Supelco
Vanillic acid, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
(−)-Epicatechin, ≥98% (HPLC), from green tea
Sigma-Aldrich
(−)-Epicatechin, ≥90% (HPLC)
Sigma-Aldrich
β-Glucuronidase from Helix pomatia, Type H-3, aqueous solution, ≥90,000 units/mL
Sigma-Aldrich
Vanillic acid, ≥97%, FG
Supelco
Mettler-Toledo Calibration substance ME 18555, Benzoic acid, analytical standard, (for the calibration of the melting point system), traceable to primary standards (LGC)
Sigma-Aldrich
3-Hydroxy-4-methoxycinnamic acid, predominantly trans, 97%
Sigma-Aldrich
3,4-Dihydroxyhydrocinnamic acid, 98%
Sigma-Aldrich
Benzoic acid, purified by sublimation, ≥99%
Sigma-Aldrich
Shikimic acid, ≥99%
Supelco
(−)-Epigallocatechin gallate, analytical standard
Supelco
Gallic acid, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
4-Methoxyphenylacetic acid, ReagentPlus®, 99%
Sigma-Aldrich
1,2-Dihydroxybenzene, ReagentPlus®, ≥99%
Sigma-Aldrich
Benzoic acid, ReagentPlus®, 99%
Sigma-Aldrich
4-Methoxycinnamic acid, predominantly trans, 99%
Sigma-Aldrich
3-(4-Hydroxyphenyl)propionic acid, 98%
Sigma-Aldrich
3-Hydroxybenzoic acid, ReagentPlus®, 99%