About This Item
UNSPSC Code:
12352200
NACRES:
NB.21
material
PTFE frit
Quality Level
Agency
suitable for EPA 533
product line
Visiprep™
technique(s)
solid phase extraction (SPE): suitable
application(s)
PFAS testing
food and beverages
compatibility
for use with 3 or 6 mL SPE tubes (includes 4 adapters)
technique used for transfers 4 large volume samples
Looking for similar products? Visit Product Comparison Guide
General description
For continuous "hands off" direct transfer of multiple liquid samples
A Visiprep large volume sampler enables you to transfer low viscosity samples directly from any sample container to conventional solid phase extraction tubes on a Visiprep SPE vacuum manifold.
Two samplers are available. One sampler has three tube adapters compatible with 12mL, 20mL, or 60mL polypropylene SPE tubes. Simultaneous extraction of 12 samples on a 12-port Visiprep manifold requires four of these samplers. The other sampler has four tube adapters for 3mL or 6mL SPE tubes. To simultaneously extract 12 samples, three samplers are required.
The samplers consist of 1/8-inch PTFE tubing with a screw fitting at one end and a stainless steel weight at the other end. To use the sampler, feed the weighted end into a sample container until it touches the bottom. Insert the tube adapters into the conditioned SPE tubes on your Visiprep manifold. Turn on the vacuum to the Visiprep manifold and open the manifold flow control valves, and the samples will be delivered to the SPE tubes. The flow rate of sample through each tube can be independently controlled by using the flow control valves. Both the screw fittings and the PTFE tubing on the samplers are colorcoded for easy sample identification.
Also fits Preppy SPE Vacuum Manifold.
Note: The Visiprep Large Volume Sampler can only be used with polypropylene SPE tubes. You must equip alternate manifold valves with long stem flow control knobs to accommodate 12 mL, 20 mL, or 60 mL SPE tubes.
A Visiprep large volume sampler enables you to transfer low viscosity samples directly from any sample container to conventional solid phase extraction tubes on a Visiprep SPE vacuum manifold.
Two samplers are available. One sampler has three tube adapters compatible with 12mL, 20mL, or 60mL polypropylene SPE tubes. Simultaneous extraction of 12 samples on a 12-port Visiprep manifold requires four of these samplers. The other sampler has four tube adapters for 3mL or 6mL SPE tubes. To simultaneously extract 12 samples, three samplers are required.
The samplers consist of 1/8-inch PTFE tubing with a screw fitting at one end and a stainless steel weight at the other end. To use the sampler, feed the weighted end into a sample container until it touches the bottom. Insert the tube adapters into the conditioned SPE tubes on your Visiprep manifold. Turn on the vacuum to the Visiprep manifold and open the manifold flow control valves, and the samples will be delivered to the SPE tubes. The flow rate of sample through each tube can be independently controlled by using the flow control valves. Both the screw fittings and the PTFE tubing on the samplers are colorcoded for easy sample identification.
Also fits Preppy SPE Vacuum Manifold.
Note: The Visiprep Large Volume Sampler can only be used with polypropylene SPE tubes. You must equip alternate manifold valves with long stem flow control knobs to accommodate 12 mL, 20 mL, or 60 mL SPE tubes.
Application
Visiprep™ large Volume Sampler was used to extract and determine estrone in water using solid-phase extraction-enzyme-linked immunosorbent assay (SPE-ELISA). It was also used in extraction of polar pesticides from rainwater samples, during extract analysis by LC-MS-MS coupled with electrospray ionization.
Legal Information
Visiprep is a trademark of Sigma-Aldrich Co. LLC
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
R Bossi et al.
Journal of chromatography. A, 957(1), 27-36 (2002-07-10)
A new LC-MS-MS method for analysis of rainwater has been developed and validated for 53 pesticides, degradation products of pesticides and selected nitrophenols. The method was used to monitor the concentration of pesticides in rainwater at one location near Roskilde
Development of a solid-phase extraction-enzyme-linked immunosorbent assay method for the determination of estrone in water.
Li, Zhilan, et al.
Analytica Chimica Acta, 503, 171-177 (2004)