Histopaque®-1119

sterile-filtered, density: 1.119 g/mL

Sign Into View Organizational & Contract Pricing

UNSPSC Code:
12352207
NACRES:
NA.75

sterility

sterile-filtered

Quality Level

form

liquid

shelf life

Expiry date on the label.

impurities

endotoxin, tested

density

1.119 g/mL

application(s)

hematology
histology

storage temp.

2-8°C

General description

Histopaque®-1119 is a sterile, endotoxin tested, ready-to-use medium. This solution consists of polysucrose and sodium diatrizoate, adjusted to a density of 1.119 g/mL and pH 8.8–9.0.

Application

Histopaque®-1119 is suitable for use in conjunction with Histopaque-1077 as it facilitates the rapid recovery of viable mononuclear cells and granulocytes from small volumes of whole blood or bone marrow

Features and Benefits

Histopaque®-1119 offers numerous advantages, such as:
  • Optimal recovery of viable cells
  • Permits selective separation of blood cell types
  • Prevents cell distortion
  • Preserves cell viability
  • Minimal extraneous cell interference
  • Reproducible performance from batch to batch
  • Sterile-filtered and endotoxin-tested
  • Stable at 2-8°C for at least 2 years when protected from light

Principle

The process involves the formation of a double gradient on layering an equal volume of Histopaque-1077 over Histopaque-1119. Anticoagulated whole blood is carefully layered onto the upper Histopaque-1077 medium. Upon centrifugation, the erythrocytes are aggregated by polysucrose and thus rapidly sediment. Granulocytes are found at the lower Histopaque-1077/1119 interface; whereas, lymphocytes and other mononuclear cells are found at the upper plasma/Histopaque-1077 interface. Most extraneous platelets found in the upper interface are removed by low-speed centrifugation during washing steps. Erythrocyte contamination is negligible.

Legal Information

Histopaque is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Product No.
Description
Pricing

Pictograms

Corrosion

Signal Word

Warning

Hazard Statements

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

  1. Which document(s) contains shelf-life or expiration date information for a given product?

    If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.

  2. How do I get lot-specific information or a Certificate of Analysis?

    The lot specific COA document can be found by entering the lot number above under the "Documents" section.

  3. How do I find price and availability?

    There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote.  USA customers:  1-800-325-3010 or view local office numbers.

  4. What is the Department of Transportation shipping information for this product?

    Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product. 

  5. When using Product 11191, Histopaque®-1119, the mononuclear cell layers forms as expected, but the layer with the polymorphonuclear (eg, neutrophils) does not form properly.  Why?

    Technique is much more important with Histopaque® 1119.  The published product insert calls for layering in the 1119 first, then adding a layer of 1077 and then layering the blood.  If there is any mixing between the 1077 and the 1119, the procedure does not work properly.  Customers can check for the integrity of their interface by checking for Schlieren optics.  Any swirling or mixing should be evident when holding the tube up against a light source, such as a ceiling light or towards a window.  If the interface was properly prepared,  there should be a sharply demarcated line.  If swirling is present, the user should start over.  It is also important to use the gradient as soon as it is formed.  There are no chemical differences between 1077 and 1119.  They are the same product, only different densities.  If left together for any length of time the two products will start diffusing together.  When this happens the percent recovery becomes unacceptable.  The gradients must be used immediately after preparation - without delay.  Creating the gradient requires the steadiest of hands.  Until you master the technique, limit the number of samples you attempt to process in one run.  After gaining experience, the number of samples processed at one time can be increased.Some customers prefer to underlay.  This protocol starts with 1077 in the test tube.  Then a long metal cannula or a 9.5 in. Pasteur pipet is used to introduce the 1119 into the very bottom of the test tube.  Care must be taken not to introduce any air bubbles.  The air bubbles will destroy the interface.  Load ~2.9 mls of 1119 into a 9.5 in. Pasteur pipette.  With an electric pipet aid, add very slowly to the bottom of the tube. With this technique the Histopaque® 1077 is slowly pushed upwards and displaced by the Histopaque® 1119  When done properly very sharp gradients are possible.  Electric pipet aids are useful when overlaying and underlaying Histopaque®.  The release is dependent upon how slow or fast the dispensing button is applied.  Regardless of the technique employed,  it is imperative to introduce the Histopaque® slowly and smoothly.  Users trying to do this with a 10 ml pipet hooked up to a blue rubber bulb are often going to experience problems.  When dispensing,  tilt the tube slightly, touch the pipet to the Histopaque® already placed in the centrifuge tube, draw the meniscus up the side of the tube 4 or 5 mm and then allow the Histopaque® to be released.  No mixing should occur.  If dispensed too quickly,  the Histopaque®/blood will mix with the lower layer.When releasing the Histopaque® into the centrifuge tube it is beneficial to slant the tube at a 45 degree angle.  The Histopaque® is then slowly released.  When complete there should be an absolutely sharp, visible line at the interface between the Histopaque® 1077 and the Histopaque® 1119.It is imperative the blood and Histopaque® all be at room temperature.  Having either the blood or Histopaque® cold could well cause the red cell contamination to increase and the cell recovery to become unacceptable.Another tip involves the measurement of the radius for your centrifuge.  The measurement should be from the center of the spindle to the bottom of the centrifuge tube (when in the swung out position).  Calculating the radius to the top or the middle of the centrifuge tube could also account for separation problems.  It is debatable which method is correct - top, bottom or middle.  Sigma uses the bottom of the centrifuge measurement.   Some centrifuges automatically calculate rpm.  Check the owner's manual for your centrifuge to determine how the rpm calculation is performed.  Not all manufacuters use the method recommended by Sigma-Aldrich.If you are collecting your blood with a syringe, switch over to a vacuum tube.  Use the freshest blood possible, but do allow the blood to reach room temperature.

  6. Can the procedure for using Product 11191, Histopaque®-1119, be used successfully with species such as rats and mice?

    The Histopaque 1119-1 procedure was developed for use with human blood.  Due to the lower number of circulating neutrophils in rat or mouse peripheral blood, the technique tends not to work as well with rats or mice.

  7. When using Product 11191, Histopaque®-1119, what is the expected percent recovery for the band containing neutrophils.

    No percent recovery data has been generated.  Due to the importance of technique with the Histopaque 1119-1, percent recovery varies with the skill of the operator.

  8. The Product 11191, Histopaque®-1119, froze in transit.  Is the product still suitable for use?

    Mix the bottles upon receipt several times to ensure the product is uniform.  The products are shipped ambient and gradients in situ can form if the solution freezes during transport. As long as the bottle has not broken and no precipitate is noted, the product is suitable for use after slowly thawing and mixing.

  9. Can the procedure for Product 11191, Histopaque®-1119, be performed using the various Accuspin products?

    No.  Accuspin products are intended for use with just a single density gradient - such as Histopaque® 1077.

  10. My question is not addressed here, how can I contact Technical Service for assistance?

    Ask a Scientist here.

Yuan Li et al.
BMC genomics, 16, 369-369 (2015-05-10)
Understanding genetic determinants of a microbial phenotype generally involves creating and comparing isogenic strains differing at the locus of interest, but the naturally existing genomic and phenotypic diversity of microbial populations has rarely been exploited. Here we report use of
Ulrich Flögel et al.
Circulation, 118(2), 140-148 (2008-06-25)
In this study, we developed and validated a new approach for in vivo visualization of inflammatory processes by magnetic resonance imaging using biochemically inert nanoemulsions of perfluorocarbons (PFCs). Local inflammation was provoked in 2 separate murine models of acute cardiac
Atsushi Masuda et al.
Nutrients, 11(5) (2019-05-15)
Long-term exposure to a high starch, low-protein diet (HSTD) induces body weight gain and hyperinsulinemia concomitantly with an increase in β-cell mass (BCM) and pancreatic islets number in mice; however, the effect of short-term exposure to HSTD on BCM and
Darin Quach et al.
Journal of bacteriology, 191(7), 2023-2032 (2008-12-31)
Group B Streptococcus (GBS) is major cause of invasive disease in newborn infants and the leading cause of neonatal meningitis. To gain access to the central nervous system (CNS), GBS must not only subvert host defenses in the bloodstream but
Matthew C Hyman et al.
The Journal of clinical investigation, 119(5), 1136-1149 (2009-04-22)
Leukocyte and platelet accumulation at sites of cerebral ischemia exacerbate cerebral damage. The ectoenzyme CD39 on the plasmalemma of endothelial cells metabolizes ADP to suppress platelet accumulation in the ischemic brain. However, the role of leukocyte surface CD39 in regulating

Articles

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Protocols

This troubleshooting guide addresses the most common sources of error observed when using Histopaque but is not meant to be a comprehensive list.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service