Skip to Content

Dear Customer:

The current international situation is complex and volatile, and uncertain tariff policies may potentially impact our product prices. Given these uncertainties, we value your understanding regarding order-related matters.

If you decide to place an order during this period, we reserve the right to adjust the price based on the evolving situation. We understand that market changes may cause inconvenience. We will negotiate with you if there’s a significant price fluctuation due to tariff policy changes before the order’s actual delivery, and in such cases we may adjust or cancel the order as necessary.

We are planning system maintenance between Friday, Apr 11 at 9:00 PM CDT and Saturday, Apr 12 at 9:00 AM CDT. This will impact both web and offline transactions, including online orders, quotes, price and availability checks, and order status inquiries. We apologize for any inconvenience.

Merck
CN
All Photos(2)

Key Documents

SCNY00020

Millipore

Millipore® Steriflip® Vacuum Tube Top Filter

pore size 20.0 μm, Nylon membrane (net), funnel capacity 50 mL, pack of 25 ea

Synonym(s):

Steriflip® Nylon Net Sterile Centrifuge Tube Top Filter Unit, tube top sterile filter unit, tube top vacuum filter, tube top vacuum sterile filtering unit

Sign Into View Organizational & Contract Pricing

Select a Size

1 EA
CN¥1,118.65

CN¥1,118.65


Please contact Customer Service for Availability


Select a Size

Change View
1 EA
CN¥1,118.65

About This Item

UNSPSC Code:
41104914
eCl@ss:
32031602
NACRES:
NB.24

CN¥1,118.65


Please contact Customer Service for Availability

material

Nylon membrane (net)
acrylic housing
polypropylene

Quality Level

sterility

sterile

product line

Steriflip®

feature

holdup volume 0.6 mL
hydrophilic

packaging

pack of 25 ea

parameter

45 °C max. temp.

technique(s)

sterile filtration: suitable

H

138 mm

capacity

50 mL

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
AB9076AB5882AB9074
antibody form

serum

antibody form

serum

antibody form

affinity purified immunoglobulin

antibody form

serum

species reactivity

mouse, human

species reactivity

mouse, rat, human

species reactivity

rat

species reactivity

human, mouse

clone

polyclonal

clone

polyclonal

clone

polyclonal

clone

polyclonal

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

Gene Information

dog ... Itpr1(476548)
human ... ITPR1(3708)
mouse ... Itpr1(16438)
rat ... Itpr1(25262)

Gene Information

human ... ITPR3(3710)
mouse ... Itpr3(16440)
rat ... Itpr3(25679)

Gene Information

human ... ITPR1(3708)

Gene Information

human ... ITPR2(3709)

General description

The Steriflip® filter unit is designed to work with standard 50 mL centrifuge tubes, which eliminates sample transfer. It is useful for sterilization of aqueous solutions (up to 50 ml), sterile filtration of small batches of culture media, sterile filtration of buffers with high-value protein or small molecule components, and cell isolation.

Application

For Research Use Only

Steriflip® Sterile Centrifuge Tube Top Filter Unit has been used:

  • in cell loading and image acquisition[1]
  • in the isolation and culture of retinal ganglion cells (RGCs) and amacrine cells (ACs) from adult mouse retinas[2]
  • for the isolation of tumors cells post digestion[3]

Features and Benefits

  • Eliminates messy sample transfer via a simple vacuum-assisted, closed system
  • Can isolate cells from cellular debris using any of the various pore-sized nylon net filters
  • Ideal for sterilizing small batches of culture media
  • Attaches to any standard 50 mL centrifuge tube, eliminating unnecessary materials, time, and risk of spillage

Legal Information

Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Steriflip is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Stephen K Jones et al.
Bio-protocol, 8(7) (2018-05-18)
Whole-lifespan single-cell analysis has greatly increased our understanding of fundamental cellular processes such as cellular aging. To observe individual cells across their entire lifespan, all progeny must be removed from the growth medium, typically via manual microdissection. However, manual microdissection
Bing Guo et al.
Animal models and experimental medicine, 1(2), 134-142 (2019-03-21)
Colorectal cancer (CRC) is the third most commonly diagnosed cancer in males and the second in females worldwide in 2012. In the past 20 years, strong evidence suggests that cancer stem cells are the main culprit of cancer metastasis, chemotherapy resistance
Yong H Park et al.
PloS one, 15(12), e0242426-e0242426 (2020-12-08)
Cell culture is widely utilized to study the cellular and molecular biology of different neuronal cell populations. Current techniques to study enriched neurons in vitro are primarily limited to embryonic/neonatal animals and induced pluripotent stem cells (iPSCs). Although the use

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service