MXRDP2KT01

Millipore

Milliflex® Rapid System 2.0

for use with Milliflex Oasis®, suitable for bioburden testing, sterility testing

Sign Into View Organizational & Contract Pricing


About This Item

UNSPSC Code:
41116129
NACRES:
NB.79

AC/DC input

100 V / 230 V, 50-60 Hz

Agency

EP 2.6.1
USP 71
71

product line

Milliflex®

packaging

pkg of 1 kit

parameter

10 kg operating weight (22 lb) (Autospray Station)
5 kg operating weight (11 lb) (Detection Tower)

technique(s)

Rapid Sterility Testing: suitable

H × W × D

31 cm (12 in.) × 21 cm (8 in.) × 40 cm (16 in.), Auto Spray Station
35 cm (14 in.) × 30 cm (12 in.) × 13 cm (5 in.), Detection Tower

application(s)

bioburden testing
sterility testing

pharmaceutical
water monitoring

compatibility

for use with Milliflex Oasis®

General description

Milliflex® Rapid 2.0 Kit is an automated solution for rapid detection, imaging, and quantification of viable microbes in filterable solutions.
The detection method is based on highly sensitive ATP bioluminescence technology. The ATP method is regulatory compliant, highly reliable, and consistent with the detection rates matching the standards of current compendial testing methods.
The conventional way of visual evaluation is replaced by Complementary Metal Oxide Semiconductor (CMOS) in Milliflex® Rapid system. The state-of-the-art image analysis and optimized reagents require reduced incubation time for viable microbial detection.
The image analysis software intensifies (~1000 times) the bioluminescence from each microbial micro-colony and captures the light signals emitted by the microbes. The software enumerates the colonies and displays results as CFU (colony forming unit).

Application

Milliflex® Rapid 2.0 system is a perfect rapid solution used for bioburden and sterility testing. The system is compatible with a wide range of filterable samples from pharmaceutical, beverage, and personal care industries.

Features and Benefits

Milliflex® Rapid 2.0 system has the following features and benefits:
  • Consistent, fast, and reproducible results.
  • Correlation of CFU counts with that of traditional methods.
  • Data Integrity Software compliant with 21 CFR Part 11.
  • Easy Handling and Validation.

Components

Milliflex® Rapid 2.0 Kit includes the following components:
  • Detection Tower -MXRDP2DT00)
  • Auto Spray station - MXRP2SPRKT
  • 2 x Power Supplies required (not included, sold separately, region specific under MXRPWRSP--)

Other Notes

Download the Milliflex® Rapid System 2.0 software from here.

Legal Information

MILLIFLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIFLEX OASIS is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Product No.
Description
Pricing

Regulatory Information

新产品

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Articles

Critical points for laboratories to consider when assessing bacteria levels in purified water and attempting to optimize the microbiology process.

Related Content

The automated Milliflex® Rapid system can get you bioburden testing and sterility testing results days earlier. Its proven technology rapidly and accurately detects microorganisms in sterility, bioburden, in-process and product release testing.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service