KTGRA04TH3
Aervent® 0.2 µm, Opticap® XL Capsule
Opticap® XL 4, inlet connection diam. 1.5 in., pore size 0.2 μm, cartridge nominal length 4 in. (10 cm)
Synonym(s):
Opticap XL 4 with Aervent - 4" 0.2um TC/HB 3pk
About This Item
Recommended Products
material
PTFE
polypropylene
polypropylene housing
polypropylene vent cap
silicone seal
Quality Level
sterility
non-sterile
Sterilization Compatibility
autoclavable compatible
product line
Opticap® XL 4
feature
hydrophobic
manufacturer/tradename
Opticap®
parameter
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.1 bar max. differential pressure (60 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
80 psig max. inlet pressure
technique(s)
gas filtration: suitable
L
7.7 in.
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | LSMLS | MSMLS06 | MSMLS02 |
---|---|---|---|
manufacturer/tradename IROA Technologies | manufacturer/tradename IROA Technologies | manufacturer/tradename IROA Technologies | manufacturer/tradename IROA Technologies |
plate size 96 wells | plate size 96 wells | plate size 96 wells | plate size 96 wells |
shipped in dry ice | shipped in dry ice | shipped in dry ice | shipped in dry ice |
storage temp. −20°C | storage temp. −20°C | storage temp. −20°C | storage temp. −20°C |
General description
Packaging
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Preparation Note
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Legal Information
Disclaimer
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service