If you decide to place an order during this period, we reserve the right to adjust the price based on the evolving situation. We understand that market changes may cause inconvenience. We will negotiate with you if there’s a significant price fluctuation due to tariff policy changes before the order’s actual delivery, and in such cases we may adjust or cancel the order as necessary.

For important updates on recent policy changes, please click here for more details.

Merck
CN
All Photos(1)

Key Documents

CR03M0203

Millipore

Polygard® CR Cartridge Filter

pore size 3.0 μm, cartridge nominal length 2 in. (5 cm), Code M (2-118; O-rings)

Synonym(s):

Polygard-CR Cartridge Filter 2 in. 3.0 μm Code M Silicone

Sign Into View Organizational & Contract Pricing

Select a Size

50 μG
CN¥1,033.50
250 μG
CN¥3,704.33

CN¥1,033.50


Please contact Customer Service for Availability


Select a Size

Change View
50 μG
CN¥1,033.50
250 μG
CN¥3,704.33

About This Item

UNSPSC Code:
23151806
eCl@ss:
32031690

CN¥1,033.50


Please contact Customer Service for Availability

material

polypropylene
silicone seal

Quality Level

feature

hydrophilic

manufacturer/tradename

Polygard

parameter

4.8 bar max. differential pressure (70 psid) at 25 °C
4.8 bar max. inlet pressure (70 psi) at 25 °C

cartridge nominal length

2 in. (5 cm)

diam.

7.0 cm (2.75 in.)

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

gravimetric extractables

≤50 mg

pore size

3.0 μm nominal pore size
3.0 μm pore size

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
HCVD4MAG67KHCVD3MAG67KHCVD2MAG67K
assay range

accuracy: 100%
(CK-MB), accuracy: 102%
(Oncostatin (OSM)), accuracy: 96%
(FABP3), accuracy: 97%
(NT proBNP), standard curve range: 2.7-2,000 pg/mL
(Placental Growth Factor (PlGF)), standard curve range: 6.9-5,000 pg/mL
(CXCL6, Oncostatin (OSM)), standard curve range: 685.9-500,000 pg/mL
(FABP4), inter-assay cv: <20%
intra-assay cv: <10%, accuracy: 103%
(CXCL6/GCP-2), standard curve range: 137.2-100,000 pg/mL
(FABP3), standard curve range: 68.6-50,000 pg/mL
(BNP, CK-MB, Troponin I (TnI)), accuracy: 102%
(LIGHT), standard curve range: 34.3-25,000 pg/mL
(NT proBNP, CXCL16, Endocan-1 (ESM-1), LIGHT), accuracy: 96%
(Placental Growth Factor (PlGF))

assay range

accuracy: 103%
(Thrombomodulin), accuracy: 104%
(Pentraxin-3 (PTX3)), accuracy: 104%
(Tissue Factor (TF)), accuracy: 106%
(Pecam-1), accuracy: 109%
(sE-Selectin), standard curve range: 0.01-5 ng/mL
(Troponin T (TnT)), standard curve range: 0.04-30 ng/mL
(Follistatin (FST)), standard curve range: 0.14-100 ng/mL
(Pentraxin-3 (PTX3) & Tissue Factor (TF)), standard curve range: 0.27-200 ng/mL
(Pecam-1), standard curve range: 0.34-250 ng/mL
(Thrombomodulin), standard curve range: 2.7-2,000 ng/mL
(sE-Selectin), inter-assay cv: <20%
intra-assay cv: <10%

assay range

accuracy: 102%
(Haptoglobin), accuracy: 109%
(AGP), accuracy: 113%
(Platelet Factor-4), accuracy: 117%
(Adipsin), standard curve range: 0.004-15 ng/mL
(L-Selectin & SAP), standard curve range: 0.012-50 ng/mL
(CRP), standard curve range: 0.037-150 ng/mL
(PF4), standard curve range: 0.061-250 ng/mL
(HPTGN), standard curve range: 0.098-400 ng/mL
(AGP & Adipsin), standard curve range: 0.244-1,000 ng/mL
(Fetuin A & vWF), standard curve range: 0.488-2,000 ng/mL
(A2M)

assay range

accuracy: 88%
(Myoglobin), accuracy: 90%
(P-selectin), accuracy: 98%
(GDF-15), standard curve range: 0.0005-2.5 ng/mL
(GDF-15), standard curve range: 0.012-50 ng/mL
(Lipocalcin-2/NGAL), standard curve range: 0.024-100 ng/mL
(Myoglobin & MPO), standard curve range: 0.085-350 ng/mL
(sICAM-1), standard curve range: 0.122-500 ng/mL
(sVCAM-1), standard curve range: 0.244-1,000 ng/mL
(D-dimer, SAA & P-selectin), standard curve range: 1.221-5,000 ng/mL
(ADAMTS 13), inter-assay cv: <20%
intra-assay cv: <15%

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

General description

The Polygard® CR Cartridge Filter products are nominally rated filters designed for particle removal applications in liquids and gases. The graded-density depth structure of Polygard-CR filter media provides maximum filtration capacity, a 3.0 μm pore size and the all-polypropylene construction offers low extractables levels and broad chemical compatibility.

Polygard-CR cartridge filters provide high throughput with 4.8 bar max. differential pressure (70 psid) at 25 °C.

Typical Applications
Polygard-CR high-efficiency cartridge filters, composed of graded density polypropylene media are widely used in the beverage industry for liquid and gas filtration applications to protect tighter filters.

Regulatory Compliance
Polygard® CR Cartridge Filters are designed, developed, and manufactured in accordance with a Quality Management System approved by an accredited registering body to an ISO 9000 Quality Systems Standard and are shipped with a Certificate of Quality. Each cartridge filter is supported by a Validation Guide for compliance with regulatory requirements.

For traceability and easy identification, each filter is marked with identifying characteristics.

Multiple Formats Available
Polygard-CR product line offers a full range of filtration areas is available to suit varying application requirements. A variety of connection options are offered for easy adaptation to existing housings.

These devices have been developed to minimize hold-up volume when evaluating multiple media configurations.

Preparation Note

Sanitization Protocol
30 min with hot water @ 80 °C
Sterilization Method
10 autoclave cycles or SIP @ 126 °C for 30 min

Analysis Note

Gravimetric Extractables: after 24-h soak in water
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L

Legal Information

POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

  • Certificates of Analysis (COA)

    Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

    Already Own This Product?

    Find documentation for the products that you have recently purchased in the Document Library.

    Visit the Document Library

    Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

    Contact Technical Service